{"id":42107,"date":"2015-09-17T11:25:58","date_gmt":"2015-09-17T16:25:58","guid":{"rendered":"https:\/\/content.findlaw-admin.com\/ability-legal\/contracts\/uncategorized\/build-operate-and-transfer-project-agreement-national-power.html"},"modified":"2015-09-17T11:25:58","modified_gmt":"2015-09-17T16:25:58","slug":"build-operate-and-transfer-project-agreement-national-power","status":"publish","type":"corporate_contracts","link":"https:\/\/corporate.findlaw.com\/contracts\/operations\/build-operate-and-transfer-project-agreement-national-power.html","title":{"rendered":"Build, Operate and Transfer Project Agreement &#8211; National Power Corp. and Hopewell Project Management Co. Ltd."},"content":{"rendered":"<pre>                            DATED 16TH NOVEMBER, 1988\n\n\n                       BUILD, OPERATE AND TRANSFER (\"BOT\")\n\n                                PROJECT AGREEMENT\n\n                                       for\n\n                           A GAS TURBINE POWER STATION\n\n                               IN NAVOTAS, MANILA\n\n                                                              \n\n                                     BETWEEN\n\n                           NATIONAL POWER CORPORATION\n\n                                       AND\n\n                   HOPEWELL PROJECT MANAGEMENT COMPANY LIMITED\n\n\n\n                                 Clifford Chance\n                                    Hong Kong\n\n\n\n\n\n   2\n\n\n                                TABLE OF CONTENTS\n\n<\/pre>\n<table>\n<caption>\nClause                              Heading                                              Page<br \/>\n&#8212;&#8212;                              &#8212;&#8212;-                                              &#8212;-<br \/>\n<s>      <c>                                                                             <c><br \/>\n1.       Definition of Terms &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.          1<\/p>\n<p>2.       The Project &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;          5<\/p>\n<p>3.       Construction of the Power Station &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;..          6<\/p>\n<p>4.       Specifications and Operating Parameters &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;..          8<\/p>\n<p>5.       Construction Timetable &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.          8<\/p>\n<p>6.       Testing &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.          9<\/p>\n<p>7.       Conditions Precedent &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;         10<\/p>\n<p>8.       Operation of the Power Station &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;..         13<\/p>\n<p>9.       Supply of Fuel &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;         14<\/p>\n<p>10.      Supply of Electricity &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;..         15<\/p>\n<p>11.      Fees &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.         15<\/p>\n<p>12.      Foreign Exchange &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.         16<\/p>\n<p>13.      Insurance &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;..         17<\/p>\n<p>14.      Transfer of Ownership &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;..         17<\/p>\n<p>15.      Liability &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;..         18<\/p>\n<p>16.      Force Majeure &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.         19<\/p>\n<p>17.      Buyout &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;..         20<\/p>\n<p>18.      Change in Circumstances &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;         21<\/p>\n<p>19.      Benefit of Agreement &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;         22<\/p>\n<p>20.      Warranty &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;         22<\/p>\n<p>21.      Notices &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.         23<\/p>\n<p>22.      Dispute Resolution &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;..         23<\/p>\n<p>23.      Law &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;..         23<\/p>\n<p>24.      Jurisdiction &#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;..         24<br \/>\n<\/c><\/c><\/s><\/caption>\n<\/table>\n<p>                                       (i)<br \/>\n   3<\/p>\n<p>                                TABLE OF CONTENTS<\/p>\n<table>\n<caption>\nSchedules                                     Heading                                       Page<br \/>\n&#8212;&#8212;&#8212;                                     &#8212;&#8212;-                                       &#8212;-<br \/>\n<s>                       <c>                                                               <c><br \/>\nFIRST SCHEDULE            &#8211;   Project Scope and Specifications&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;       25<\/p>\n<p>SECOND SCHEDULE           &#8211;   Operating Parameters&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;       30<\/p>\n<p>THIRD SCHEDULE            &#8211;   Penalty of HOPEWELL on Delay<br \/>\n                              of Completion Date&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;..       34<\/p>\n<p>FOURTH SCHEDULE           &#8211;   Specifications for Fuel Supply<br \/>\n                              and Start Up Electricity&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;..       35<\/p>\n<p>FIFTH SCHEDULE            &#8211;   Transmission Line Specifications&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;       38<\/p>\n<p>SIXTH SCHEDULE            &#8211;   Electricity Delivery Procedures&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.       39<\/p>\n<p>SEVENTH SCHEDULE          &#8211;   Measurement and Recording<br \/>\n                              of Electricity&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;       42<\/p>\n<p>EIGHTH SCHEDULE           &#8211;   Delivery of Power and Energy&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.       43<\/p>\n<p>NINTH SCHEDULE            &#8211;   Documentary Requirements<br \/>\n                              for the Effective Date&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.       48<\/p>\n<p>TENTH SCHEDULE            &#8211;   Insurance&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;..       50<\/p>\n<p>ELEVENTH SCHEDULE         &#8211;   Form of Performance Undertaking&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.       51<\/p>\n<p>TWELFTH SCHEDULE          &#8211;   Form of Accession Undertaking&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;       53<\/p>\n<p>THIRTEENTH SCHEDULE       &#8211;   Form of Legal Opinion of<br \/>\n                              NAPOCOR&#8217;s General Counsel&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.       56<\/p>\n<p>FOURTEENTH SCHEDULE       &#8211;   Testing Procedures&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;..       58<\/p>\n<p>FIFTEENTH SCHEDULE        &#8211;   Sample Computations of Monthly<br \/>\n                              Billings, Start-Up Charges,<br \/>\n                              Penalties and Bonuses&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;..       63<br \/>\n<\/c><\/c><\/s><\/caption>\n<\/table>\n<table>\n<caption>\nFIGURES<br \/>\n&#8212;&#8212;-<br \/>\n<s>            <c><br \/>\nFigure 1       &#8211;    Location Plan<\/p>\n<p>Figure 2       &#8211;    Temporary Fence Detail<\/p>\n<p>Figure 3       &#8211;    One Line Diagram<\/p>\n<p>Figures 4\/4A   &#8211;    Scope of Supply<\/p>\n<p>Figure 5       &#8211;    Communication<\/p>\n<p>Figure 6       &#8211;    Fuel Oil System<\/p>\n<p>Figure 7       &#8211;    Metering<br \/>\n<\/c><\/s><\/caption>\n<\/table>\n<p>                                      (ii)<br \/>\n   4<\/p>\n<p>NOW ALL MEN BY THESE PRESENTS<\/p>\n<p>This Agreement is made and entered into by and between:<\/p>\n<p>         HOPEWELL PROJECT MANAGEMENT COMPANY LIMITED, a private corporation,<br \/>\n         duly organized and existing under the laws of Hong Kong with its<br \/>\n         principal address at 64th Floor, Hopewell Centre, 183 Queen&#8217;s Road<br \/>\n         East, Hong Kong represented by its Managing Director, MR. GORDON WU,<br \/>\n         who is duly authorised to represent it in this Agreement, hereinafter<br \/>\n         referred to as HOPEWELL<\/p>\n<p>                                     &#8211; and &#8211;<\/p>\n<p>         NATIONAL POWER CORPORATION, a government owned and controlled<br \/>\n         corporation existing under and by virtue of Republic Act No. 6395, as<br \/>\n         amended, with its principal office at the corner of Agham Road and<br \/>\n         Quezon Avenue, Diliman, Quezon City, Philippines, represented herein by<br \/>\n         its President, MR. ERNESTO M. ABOITIZ, who is duly authorised to<br \/>\n         represent it in this Agreement, hereinafter referred to as NAPOCOR.<\/p>\n<p>                                    RECITALS<\/p>\n<p>         WHEREAS NAPOCOR and Hopewell Holdings Limited signed a letter of intent<br \/>\non the 14th April, 1988 and a further letter dated 10th October, 1988 from<br \/>\nHopewell Holdings Limited pursuant to which they agreed, inter alia, to<br \/>\nendeavour to agree the terms whereon HOPEWELL, a subsidiary of Hopewell Holdings<br \/>\nLimited, would supply a gas turbine power station to NAPOCOR on a build, operate<br \/>\nand transfer basis.<\/p>\n<p>         WHEREAS Pursuant to the said letters HOPEWELL has agreed to supply and<br \/>\nNAPOCOR has agreed to accept a gas turbine power station upon the terms and<br \/>\nsubject to the conditions hereinafter appearing.<\/p>\n<p>         WHEREAS HOPEWELL shall cause the formation of a subsidiary Philippine<br \/>\ncorporation, to be called Hopewell Energy (Philippines) Corp., for the purpose<br \/>\nof undertaking certain of the work in respect of the building and operating of<br \/>\nthe Power Station and perform other undertakings specified in this Agreement.<\/p>\n<p>NOW IT IS HEREBY AGREED as follows:-<\/p>\n<p>1.       DEFINITION OF TERMS<\/p>\n<p>1.01     In this Agreement and in the recitals hereto:<\/p>\n<p>         &#8220;ACCESSION UNDERTAKING&#8221; means an agreement in the form substantially<br \/>\n         set out in the Twelfth Schedule pursuant to which<\/p>\n<p>   5<\/p>\n<p>HOPEWELL PHILIPPINES agrees to become a party hereto as therein provided;<\/p>\n<p>&#8220;AVAILABILITY&#8221; means the maximum generating capacity from time to time of the<br \/>\nPower Station as determined pursuant to the Availability Schedule;<\/p>\n<p>&#8220;AVAILABILITY SCHEDULE&#8221; means the schedule of the generating capacity of the<br \/>\nPower Station agreed pursuant to Clause 8.08;<\/p>\n<p>&#8220;BLACK START&#8221; means the starting of the turbines of the Power Station in<br \/>\ncircumstances where, due to failure of other power stations connected to the<br \/>\nLuzon grid, it is impossible for NAPOCOR to supply the necessary start-up<br \/>\nelectricity;<\/p>\n<p>&#8220;BOI&#8221; means the Board of Investments of the Republic of the Philippines;<\/p>\n<p>&#8220;CAPACITY FEES&#8221; means the fees payable by NAPOCOR to HOPEWELL in respect of the<br \/>\nContracted Capacity as provided in Clause 11;<\/p>\n<p>&#8220;CENTRAL BANK&#8221; means the Central Bank of the Philippines;<\/p>\n<p>&#8220;COMPLETION DATE&#8221; means the day upon which HOPEWELL certifies that the Power<br \/>\nStation, capable of operating in accordance with the Operating Parameters, has<br \/>\nsuccessfully completed its testing;<\/p>\n<p>&#8220;CONTRACTED CAPACITY&#8221; shall have the meaning given to it in the Eighth Schedule;<\/p>\n<p>&#8220;CO-OPERATION PERIOD&#8221; means the period of twelve (12) years from the later of<br \/>\nthe Target Completion Date and the Completion Date, as the same may be extended<br \/>\nfrom time to time pursuant to the terms hereof;<\/p>\n<p>&#8220;DELIVERY POINTS&#8221; means the metering points referred to in the Seventh Schedule;<\/p>\n<p>&#8220;DOWNTIME&#8221; shall have the meaning given to it in the Sixth Schedule;<\/p>\n<p>&#8220;EFFECTIVE DATE&#8221; means the date on which NAPOCOR and HOPEWELL certify that all<br \/>\nthe conditions contained in Clauses 7.01, 7.02, 7.03 and 7.04 have been<br \/>\nfulfilled to the satisfaction of NAPOCOR in the case of Clause 7.01 and<br \/>\nfulfilled or waived to the satisfaction of HOPEWELL in the case of Clauses 7.02,<br \/>\n7.03 and 7.04;<\/p>\n<p>&#8220;EMERGENCY&#8221; means unforeseen circumstances affecting the Luzon grid which<br \/>\nreasonably require NAPOCOR to request HOPEWELL to supply it with power and<br \/>\nenergy as soon as practicable in order to avoid damage to NAPOCOR&#8217;s electric<br \/>\nsystem and\/or a failure in the continuous supply of electricity from the grid;<\/p>\n<p>                                       2<br \/>\n   6<\/p>\n<p>&#8220;ENERGY FEES&#8221; means the fees payable by NAPOCOR to HOPEWELL in respect of energy<br \/>\nsupplied to NAPOCOR as provided in Clause 11;<\/p>\n<p>&#8220;EVALUATED OPERATING HOURS&#8221; shall have the meaning given to it in the Sixth<br \/>\nSchedule;<\/p>\n<p>&#8220;FORCE MAJEURE&#8221; shall have the meaning specified in Clause 16.01;<\/p>\n<p>&#8220;FORCED OUTAGE&#8221; shall have the meaning given to it in the Sixth Schedule;<\/p>\n<p>&#8220;FORCED OUTAGE DAY&#8221; shall have the meaning given to it in the Sixth Schedule;<\/p>\n<p>&#8220;FUEL MANAGEMENT AGREEMENT&#8221; means the agreement to be entered into pursuant to<br \/>\nClause 9.06;<\/p>\n<p>&#8220;FUEL SPECIFICATIONS&#8221; means the specifications as to the quality and method of<br \/>\nstorage, supply and delivery of the fuel for the Power Station described in<br \/>\nClause 9.03 and the Fourth Schedule;<\/p>\n<p>&#8220;FUEL SUPPLY PROCEDURES&#8221; means the procedures and parameters for the supply and<br \/>\ndelivery of fuel by NAPOCOR described in Clause 9 and the Fourth Schedule;<\/p>\n<p>&#8220;HOPEWELL PHILIPPINES&#8221; means Hopewell Energy (Philippines) Corp., a Philippine<br \/>\ncorporation in the process of being formed, and which is or shall be a<br \/>\nsubsidiary of HOPEWELL;<\/p>\n<p>&#8220;MAJOR OVERHAUL&#8221; means, in relation to a turbine, the overhaul following 48,000<br \/>\nEvaluated Operating Hours;<\/p>\n<p>&#8220;MONTH&#8221; means the period commencing immediately after the taking of a photograph<br \/>\nof the electricity meters on the 25th of each calendar month, pursuant to the<br \/>\nSeventh Schedule and ending upon the taking of such photograph on the 25th of<br \/>\nthe next calendar month; in the case of the first month &#8220;MONTH&#8221; means the period<br \/>\ncommencing on the first day of the Cooperation Period and ending upon the taking<br \/>\nof a photograph of the electricity meters on the 25th of the current calendar<br \/>\nmonth (or the next calendar month if the period commenced on or after the 25th<br \/>\nof the current calendar month) and in the case of the last month &#8220;MONTH&#8221; means<br \/>\nthe period commencing immediately after the end of the immediately preceding<br \/>\nMonth and ending upon the taking of a photograph of the electricity meters on<br \/>\nthe Transfer Date;<\/p>\n<p>&#8220;NOMINAL CAPACITY&#8221; shall mean 200,000 KW;<\/p>\n<p>&#8220;OPERATING PARAMETERS&#8221; means the operating parameters of the Power Station<br \/>\ndescribed in the Second Schedule;<\/p>\n<p>                                       3<br \/>\n   7<\/p>\n<p>&#8220;PERFORMANCE UNDERTAKING&#8221; means the agreement referred to in Clause 7.03(i);<\/p>\n<p>&#8220;POWER STATION&#8221; means the power station built, or to be built, pursuant to<br \/>\nClause 2.01;<\/p>\n<p>&#8220;PRIME&#8221; means, on any day, the rate per annum which is the average of the prime<br \/>\nor equivalent rates of Citibank, N.A., New York, Bankers Trust Company, New York<br \/>\nand Manufacturers Hanover Trust Company of New York as publicly announced from<br \/>\ntime to time, in force on such date and, for the purposes of this Agreement, a<br \/>\nchange in any such rate shall be effective on and from the day on which it is<br \/>\nannounced or, if such announcement provides for such change to come into effect<br \/>\non a later date, on and from such later date;<\/p>\n<p>&#8220;PROJECT&#8221; means the design, construction, equiping, completion, testing,<br \/>\ncommissioning and operation of the Power Station;<\/p>\n<p>&#8220;PROJECT SCOPE&#8221; means the scope of the supply of work of HOPEWELL in connection<br \/>\nwith the construction of the Power Station as described in the First Schedule;<\/p>\n<p>&#8220;SITE&#8221; means the site for the Power Station at Navotas Metropolitan Manila as<br \/>\nmore particularly described in the First Schedule;<\/p>\n<p>&#8220;SPECIFICATIONS&#8221; means the specifications of the Power Station described in the<br \/>\nFirst Schedule;<\/p>\n<p>&#8220;START UP FEES&#8221; means the fees payable by NAPOCOR to HOPEWELL in respect of<br \/>\nstart ups of the gas turbines as provided in Clause 11;<\/p>\n<p>&#8220;SUPPLY PROCEDURES&#8221; means the procedures and parameters for the requesting of<br \/>\nthe supply of electricity by NAPOCOR described in Clause 10.01 and the Sixth<br \/>\nSchedule;<\/p>\n<p>&#8220;T-BILL RATE&#8221; means, in respect of any day for which interest based on such rate<br \/>\nis being calculated under this Agreement, the rate per annum at which Philippine<br \/>\nTreasury Bills (with terms of 30 days or if no such bill with a term of 30 days<br \/>\nis issued such bill which is issued having the term nearest to 30 days) were<br \/>\nissued by the Philippine Government on the Friday immediately preceding such<br \/>\nday, or, if there were no Treasury Bills issued on such Friday, on the day<br \/>\nimmediately preceding such Friday on which Treasury Bills were issued provided<br \/>\nthat if, for 30 days no Philippine Treasury Bills are issued, then &#8220;T-Bill Rate&#8221;<br \/>\nshall mean such alternative rate of interest as may be agreed between HOPEWELL<br \/>\nand NAPOCOR at such time, or, in the absence of agreement, the rate per annum<br \/>\ncertified and evidenced by HOPEWELL to be its effective cost of borrowing at<br \/>\nsuch time;<\/p>\n<p>                                       4<br \/>\n   8<\/p>\n<p>         &#8220;TARGET COMPLETION DATE&#8221; means, subject to Clause 5.02, 15th October,<br \/>\n         1989;<\/p>\n<p>         &#8220;TRANSFER DATE&#8221; means the day following the last day of the<br \/>\n         Co-operation Period; and<\/p>\n<p>         &#8220;TRANSMISSION LINE&#8221; means the transmission line to be installed and<br \/>\n         connected by NAPOCOR pursuant to Clause 3.06(iv) and having the<br \/>\n         specifications set out in the Fifth Schedule.<\/p>\n<p>1.02     Any reference in this Agreement to a &#8220;CLAUSE&#8221; or a &#8220;SCHEDULE&#8221; is a<br \/>\nreference to a clause hereof or a schedule hereto.<\/p>\n<p>1.03     In this Agreement:<\/p>\n<p>         (i)      &#8220;$&#8221; and &#8220;DOLLAR(S)&#8221; denote lawful currency of the United<br \/>\n                  States of America;<\/p>\n<p>         (ii)     &#8220;PS&#8221; and &#8220;PESO(S)&#8221; denote lawful currency of the Republic of<br \/>\n                  the Philippines;<\/p>\n<p>         (iii)    &#8220;MW&#8221; denotes a megawatt;<\/p>\n<p>         (iv)     &#8220;KW&#8221; denotes a kilowatt; and<\/p>\n<p>         (v)      &#8220;KWH&#8221; denotes a kilowatt hour.<\/p>\n<p>2.       THE PROJECT<\/p>\n<p>2.01     HOPEWELL, having inspected the Site and finding it physically suitable<br \/>\nfor the construction and operation of a gas turbine power station, shall cause<br \/>\nthe design, development, construction, completion, testing and commissioning of<br \/>\na gas turbine power station with Black Start capability, capable of operating at<br \/>\na level within the Operating Parameters and in accordance with the<br \/>\nSpecifications and the Project Scope.<\/p>\n<p>2.02     Subject as herein provided, all costs of HOPEWELL in connection with<br \/>\nthe building of the Power Station as provided in Clause 2.01 shall be borne by<br \/>\nHOPEWELL and HOPEWELL shall be responsible for arranging all necessary funding<br \/>\nincluding any available preferential credits.<\/p>\n<p>2.03     NAPOCOR shall make available the Site to HOPEWELL for the purpose of<br \/>\nbuilding and operating the Power Station at no cost to HOPEWELL for the period<br \/>\nfrom the Effective Date until the Transfer Date and HAPOCOR shall be responsible<br \/>\nfor the payment of all real estate taxes and assessments, rates and other<br \/>\ncharges in respect of the Site and the buildings and improvements thereon.<\/p>\n<p>2.04     NAPOCOR shall ensure that all necessary access to and from the Site is<br \/>\nmade available to HOPEWELL, its employees, contractors, subcontractors and<br \/>\nadvisors and that all necessary utilities as provided in Section V of the First<br \/>\nSchedule are made available at the Site as<\/p>\n<p>                                       5<br \/>\n   9<\/p>\n<p>necessary for the construction, testing and commissioning of the Power Station.<\/p>\n<p>2.05     HOPEWELL shall be responsible for the importation and transportation of<br \/>\nequipment to the Site, the obtaining of building, construction, operating and<br \/>\nother permits, licences and approvals for the Project, and of visas and work<br \/>\npermits for foreign personnel, the recruitment of local labour and compliance<br \/>\nwith all local and other regulations including the payment of all fees and costs<br \/>\nthereof.<\/p>\n<p>2.06     NAPOCOR shall supply fuel and start up electricity (through the<br \/>\ninterconnection facilities with MERALCO) of the required quantity and quality<br \/>\nand at the required time for the testing and commissioning of the Power Station,<br \/>\nshall construct, install and connect the Transmission Line and shall take all<br \/>\nelectricity generated during testing and commissioning.<\/p>\n<p>2.07     All costs of NAPOCOR (except in respect of start up electricity) in<br \/>\nconnection with its obligations under Clause 2.03, 2.04 and 2.06 shall be borne<br \/>\nby NAPOCOR.<\/p>\n<p>2.08     From the date hereof until the Transfer Date, HOPEWELL shall, directly<br \/>\nor indirectly, own the Power Station and all the fixtures, fittings, machinery<br \/>\nand equipment on the Site or used in connection with the Power Station which<br \/>\nhave been supplied by it or at its cost and it shall operate and manage the<br \/>\nPower Station for the purpose of converting fuel of NAPOCOR into electricity.<\/p>\n<p>2.09     Until the Transfer Date, NAPOCOR shall, at its own cost, supply and<br \/>\ndeliver all fuel for the Power Station and shall take all electricity generated<br \/>\nby the Power Station at the request of NAPOCOR which shall pay to HOPEWELL fees<br \/>\nas provided in Clause 11.<\/p>\n<p>2.10     During the Co-operation Period NAPOCOR shall ensure the provision of<br \/>\nall necessary utilities to the Power Station as provided in Section VI of the<br \/>\nFirst Schedule Provided that NAPOCOR shall have no liability under this<br \/>\nsub-clause where such utility is withdrawn as a result of HOPEWELL failing to<br \/>\npay for the utilization of the same.<\/p>\n<p>2.11     On the Transfer Date the Power Station shall be transferred by HOPEWELL<br \/>\nto NAPOCOR without the payment of any compensation.<\/p>\n<p>2.12     The parties hereto shall mutually collaborate with each other in order<br \/>\nto achieve the objectives of this Agreement and the performance by each of the<br \/>\nparties hereto of their respective obligations hereunder.<\/p>\n<p>3.       Construction of the Power Station<\/p>\n<p>3.01     HOPEWELL shall be responsible for the design, construction, equiping,<br \/>\ncompletion, testing and commissioning of the Power Station and shall commence<br \/>\nwork upon being instructed by NAPOCOR by instructions in writing given not later<br \/>\nthan 31st December, 1988.<\/p>\n<p>                                       6<br \/>\n   10<\/p>\n<p>3.02     In pursuance of its obligations under Clause 3.01 HOPEWELL shall have<br \/>\nfull right to:<\/p>\n<p>         (i)      call for tenders and award contracts with or without tender;<\/p>\n<p>         (ii)     arrange for the preparation of detailed designs and approve or<br \/>\n                  reject the same;<\/p>\n<p>         (iii)    appoint and remove consultants and professional advisers;<\/p>\n<p>         (iv)     purchase new and\/or refurbished equipment including the gas<br \/>\n                  turbine sets;<\/p>\n<p>         (v)      appoint, organise and direct staff, manage and supervise the<br \/>\n                  Project;<\/p>\n<p>         (vi)     enter into contracts for the supply of materials and services,<br \/>\n                  including contracts with NAPOCOR; and<\/p>\n<p>         (vii)    do all other things necessary or desirable for the completion<br \/>\n                  of the Power Station in accordance with the Specifications and<br \/>\n                  generally accepted engineering standards by the Target<br \/>\n                  Completion Date.<\/p>\n<p>3.03     In pursuance of its obligations under Clause 3.01 HOPEWELL shall, where<br \/>\npossible, award contracts to Philippine contractors and suppliers of materials<br \/>\nand services provided that, in its opinion, the quality, delivery times, costs,<br \/>\nreliability and other terms are comparable to those offered by foreign<br \/>\ncontractors and\/or suppliers.<\/p>\n<p>3.04     NAPOCOR shall be entitled at its own cost to monitor the progress and<br \/>\nquality of the construction and installation work and for this purpose HOPEWELL<br \/>\nshall:<\/p>\n<p>         (i)      ensure that NAPOCOR and any experts appointed by NAPOCOR in<br \/>\n                  connection with the Project are afforded reasonable access to<br \/>\n                  the Site at times to be agreed with HOPEWELL provided that<br \/>\n                  such access does not materially interfere with the works<br \/>\n                  comprising the Project or expose any person on the Site to any<br \/>\n                  danger;<\/p>\n<p>         (ii)     make available for inspection at the Site copies of all plans<br \/>\n                  and designs; and<\/p>\n<p>         (iii)    within two months of the completion of the Power Station,<br \/>\n                  supply NAPOCOR with one set of reproduceable copies and five<br \/>\n                  sets of white print copies (or equivalent) of all &#8220;as built&#8221;<br \/>\n                  plans and designs.<\/p>\n<p>3.05     HOPEWELL:<\/p>\n<p>         (i)      shall in no way represent to any third party that, as a result<br \/>\n                  of any review by NAPOCOR, NAPOCOR is responsible for the<br \/>\n                  engineering soundness of the Power Station; and<\/p>\n<p>                                       7<br \/>\n   11<br \/>\n         (ii)     shall, subject to the other provisions of this Agreement, be<br \/>\n                  solely responsible for the economic and technical feasibility,<br \/>\n                  operational capability and reliability of the Power Station.<\/p>\n<p>3.06     NAPOCOR shall ensure that all infrastructural requirements and<br \/>\nutilities necessary for the completion of the Power Station in accordance with<br \/>\nthe Specifications by the Target Completion Date are made available in a timely<br \/>\nfashion and accordingly shall at its own cost, inter alia:<\/p>\n<p>         (i)      give vacant possession of the Site to HOPEWELL by not later<br \/>\n                  than 15 days after the Effective Date;<\/p>\n<p>         (ii)     ensure that there is provided to the Site by not later than 15<br \/>\n                  days after the Effective Date access roads capable of taking<br \/>\n                  traffic to and from the Site and ensure that the Site is<br \/>\n                  enclosed by a temporary fence as described in the First<br \/>\n                  Schedule;<\/p>\n<p>         (iii)    ensure that there is provided to the Site water, electricity,<br \/>\n                  telephone, telex and fax as provided and at the times set out<br \/>\n                  in Section V of the First Schedule the cost of the utilization<br \/>\n                  of which and normal fees shall be for HOPEWELL&#8217;s account; and<\/p>\n<p>         (iv)     ensure that there is installed and connected a transmission<br \/>\n                  line from the outgoing gantry of the switching facility within<br \/>\n                  the Site boundary and which is capable of operating within the<br \/>\n                  specifications set out in the Fifth Schedule.<\/p>\n<p>3.07     NAPOCOR warrants and undertakes that the Site shall be suitable for the<br \/>\nconstruction and operation of the Power Station including for its construction<br \/>\nand operation within all environmental and other Philippine and local laws and<br \/>\nregulations.<\/p>\n<p>4.       SPECIFICATIONS AND OPERATING PARAMETERS<\/p>\n<p>4.01     The Power Station shall be constructed and equipped in accordance with<br \/>\nthe Specifications and Project Scope set out in the First Schedule.<\/p>\n<p>4.02     Following the Completion Date the Power Station shall be capable of<br \/>\noperating within the Operating Parameters set out in the Second Schedule.<\/p>\n<p>5.       CONSTRUCTION TIMETABLE<\/p>\n<p>5.01     The parties shall work together in order to endeavour to achieve the<br \/>\ntimely completion of the Project in accordance with the following timetable:-<\/p>\n<p>                                       8<br \/>\n   12<\/p>\n<table>\n<caption>\n<p>Stage Completed                               Date<br \/>\n&#8212;&#8212;&#8212;&#8212;&#8212;                               &#8212;-<br \/>\n<s>                                   <c><br \/>\nEffective Date                        30th November, 1988<br \/>\nMobilisation                          15th December, 1988<br \/>\nCommencement of Site Works            31st December, 1988<br \/>\nTesting for 100MW                     15th August, 1989<br \/>\nTarget Availability for 100MW         31st August, 1989<br \/>\nTesting for Completion Date            1st October, 1989<br \/>\nTarget Completion Date                15th October, 1989<br \/>\n<\/c><\/s><\/caption>\n<\/table>\n<p>5.02     In the event that the Effective Date occurs, or the instructions<br \/>\nreferred to in Clause 3.01 are given, after 30th November, 1988 each of the<br \/>\nother dates set out in Clause 5.01 shall be adjusted to occur later by the<br \/>\nnumber of days that the Effective Date occurs, or such instructions are given,<br \/>\nafter 30th November, 1988.<\/p>\n<p>5.03     In the event that, due to the fault of HOPEWELL, HOPEWELL fails to<br \/>\ncomplete the Power Station as provided in Clause 4.01 within 4 weeks of the<br \/>\nTarget Completion Date, HOPEWELL shall pay NAPOCOR for each day thereafter until<br \/>\nthe Completion Date as provided in the Third Schedule.<\/p>\n<p>5.04     In the event that, due to the fault of HOPEWELL, the Completion Date<br \/>\nhas not occurred on or before the day falling three hundred (300) calendar days<br \/>\nafter the Target Completion Date and it does not appear reasonably likely that<br \/>\nthe Completion Date will ever occur HOPEWELL shall pay to NAPOCOR the sum of<br \/>\n$4,200,000 by way of liquidated damages but shall have no other liability in<br \/>\nrespect of such failure to complete the Power Station other than that provided<br \/>\nin Clause 15.01 and upon such sum becoming payable, or being paid by HOPEWELL<br \/>\nprior to it becoming due, HOPEWELL shall have no further liability to make<br \/>\npayments pursuant to Clause 5.03.<\/p>\n<p>5.05     Upon substantial completion of the Power Station, HOPEWELL may certify<br \/>\nthat the Power Station has successfully completed its testing and that<br \/>\naccordingly the Completion Date has occurred notwithstanding that the Power<br \/>\nStation is unable to produce 200 MW or to achieve the heat rates provided in<br \/>\nSection 9 of Part A of the Second Schedule but in that event adjustments shall<br \/>\nbe made to the Capacity Fees and Energy Fees as provided in the Eighth Schedule.<\/p>\n<p>6.       TESTING<\/p>\n<p>6.01     The parties shall meet and agree procedures, standards, protective<br \/>\nsettings and a programme for the testing of the Power Station in accordance with<br \/>\nthe Fourteenth Schedule and NAPOCOR undertakes to take all electricity generated<br \/>\nduring any such testing.<\/p>\n<p>6.02     HOPEWELL shall give to NAPOCOR not less than 14 days&#8217; notice, or such<br \/>\nlesser period as the parties hereto may agree, of its intention to commence any<br \/>\ntesting.<\/p>\n<p>6.03     During the Co-operation Period, in order to ensure the proper<br \/>\nfunctioning and maintenance of the Power Station, HOPEWELL shall be<\/p>\n<p>                                       9<\/p>\n<p>   13<br \/>\nentitled to require that each gas turbine be operated for a period of two hours<br \/>\nin each Month including start up time.<\/p>\n<p>6.04     NAPOCOR shall ensure that there is made available for any testing<br \/>\nsupplies of fuel, start up electricity and water in sufficient quantity for the<br \/>\nproper carrying out of such testing and of the quality specified in the<br \/>\nSchedules hereto.<\/p>\n<p>6.05     The cost of the fuel to be supplied by NAPOCOR pursuant to Clause 6.04<br \/>\nshall be for NAPOCOR&#8217;s account.<\/p>\n<p>6.06     NAPOCOR shall ensure that the Transmission Line is installed and<br \/>\nconnected in time for the first testing to take place in accordance with the<br \/>\nagreed programme and that it is by such time capable of operating within the<br \/>\nspecifications set out in the Fifth Schedule.<\/p>\n<p>6.07     NAPOCOR and\/or its experts shall be entitled to be present at any<br \/>\ntesting.<\/p>\n<p>6.08     Forthwith upon the completion of any testing HOPEWELL shall certify<br \/>\nwhether or not the Power Station has satisfied such test and shall provide<br \/>\nNAPOCOR with a copy of such certificate.<\/p>\n<p>7.       CONDITIONS PRECEDENT<\/p>\n<p>7.01     It shall be a condition precedent to this Agreement that by 30th<br \/>\nNovember 1988, or such later date as the parties hereto may agree, the following<br \/>\nare supplied to NAPOCOR by HOPEWELL, each in form and substance satisfactory to<br \/>\nNAPOCOR or that such a condition precedent is waived by NAPOCOR:<\/p>\n<p>         (i)      copies of the Memorandum and Articles of Association of<br \/>\n                  HOPEWELL, as certified by the company secretary of HOPEWELL in<br \/>\n                  a manner satisfactory to NAPOCOR:<\/p>\n<p>         (ii)     copies of resolutions adopted by HOPEWELL&#8217;s Board of Directors<br \/>\n                  authorising the execution, delivery and performance by<br \/>\n                  HOPEWELL of this Agreement certified by the company secretary<br \/>\n                  of HOPEWELL in a manner satisfactory to NAPOCOR;<\/p>\n<p>         (iii)    approval of the Central Bank to make payments to HOPEWELL in<br \/>\n                  dollars as provided in this Agreement; and<\/p>\n<p>         (iv)     a bond or guarantee of a financial institution acceptable to<br \/>\n                  NAPOCOR in respect of HOPEWELL&#8217;s obligations under Clause<br \/>\n                  5.04.<\/p>\n<p>7.02     It shall be a condition precedent to this Agreement that by 30th<br \/>\nNovember 1988, or such later date as the parties hereto may agree, the following<br \/>\nare supplied to HOPEWELL by NAPOCOR, each in form and substance satisfactory to<br \/>\nHOPEWELL or that such a condition precedent is waived by HOPEWELL:<\/p>\n<p>                                        10<br \/>\n   14<\/p>\n<p>         (i)      copies of the Charter and By-Laws of NAPOCOR, and of<br \/>\n                  resolutions adopted by its Board of Directors authorising the<br \/>\n                  execution delivery and performance by NAPOCOR of this<br \/>\n                  Agreement, each certified by the corporate secretary of<br \/>\n                  NAPOCOR in a manner satisfactory to HOPEWELL;<\/p>\n<p>         (ii)     copies of such consents, licences, permits, approvals and<br \/>\n                  registrations by or with any governmental agency or other<br \/>\n                  authority in the Philippines as may be necessary to ensure<br \/>\n                  the validity and binding effect of this Agreement and to<br \/>\n                  permit the performance by NAPOCOR of its obligations under<br \/>\n                  this Agreement;<\/p>\n<p>         (iii)    a certificate of the corporate secretary of NAPOCOR<br \/>\n                  confirming that all necessary corporate and other approvals<br \/>\n                  and action have been duly obtained and taken for the<br \/>\n                  execution, delivery and performance by NAPOCOR of this<br \/>\n                  Agreement;<\/p>\n<p>         (iv)     a copy of the lease to NAPOCOR of the Site, certified by the<br \/>\n                  corporate secretary of NAPOCOR in a manner satisfactory to<br \/>\n                  HOPEWELL together with the agreement of the lessor and<br \/>\n                  NAPOCOR that, in the event NAPOCOR shall fail to pay any<br \/>\n                  rental or perform any of its obligations when due under the<br \/>\n                  said lease, HOPEWELL or its assignee shall be entitled, at<br \/>\n                  its sole option, to pay such rental or perform such<br \/>\n                  obligation on behalf and for the account of NAPOCOR;<\/p>\n<p>         (v)      evidence that the lease referred to in paragraph (iv) above<br \/>\n                  has been recorded in the office of the Register of Deeds and<br \/>\n                  that HOPEWELL&#8217;s interest in the Site has been duly recorded<br \/>\n                  on such lease and in the office of the Register of Deeds; and<\/p>\n<p>         (vi)     a legal opinion of NAPOCOR&#8217;s General Counsel in the form set<br \/>\n                  out in the Thirteenth Schedule.<\/p>\n<p>7.03     It shall be a condition precedent to this Agreement that by 30th<br \/>\n         November 1998, or such later date as the parties hereto may agree, the<br \/>\n         following are received by HOPEWELL, each in form and substance<br \/>\n         satisfactory to HOPEWELL or that such a condition precedent is waived<br \/>\n         by HOPEWELL:<\/p>\n<p>         (i)      a performance undertaking of the Republic of the Philippines<br \/>\n                  in respect of NAPOCOR&#8217;s obligations hereunder duly executed<br \/>\n                  and delivered by the Republic of the Philippines in the form<br \/>\n                  set out in the Eleventh Schedule;<\/p>\n<p>         (ii)     copies of all such consents, licences, permits, approvals and<br \/>\n                  registrations by or with any governmental agency or other<br \/>\n                  authority in the Philippines as may be necessary to ensure<br \/>\n                  the validity and binding effect of the Performance<br \/>\n                  Undertaking, and to permit the performance by the Republic of<br \/>\n                  the Philippines of its obligations thereunder;<\/p>\n<p>                                       11<br \/>\n   15<\/p>\n<p>         (iii)    a legal opinion of the Secretary of Justice of the Republic<br \/>\n                  of the Philippines as to the validity, enforceability and<br \/>\n                  binding effect of the Performance Undertaking in form and<br \/>\n                  substance satisfactory to HOPEWELL;<\/p>\n<p>         (iv)     the Accession Undertaking, duly executed by HOPEWELL<br \/>\n                  PHILIPPINES; and<\/p>\n<p>         (v)      each of the documents referred to in the Ninth Schedule,<\/p>\n<p>it is understood that NAPOCOR shall not be responsible to ensure that any of the<br \/>\nabove is received by HOPEWELL.<\/p>\n<p>7.04         If the Effective Date has not occurred by 30th November, 1988 it<br \/>\nshall be a condition precedent to this Agreement that HOPEWELL has notified<br \/>\nNAPOCOR that it has been able to arrange for the purchase of appropriate gas<br \/>\nturbines and auxiliaries for the construction of the Power Station.<\/p>\n<p>7.05         If, on or before the 15th January 1989, or such later date as the<br \/>\nparties hereto may agree, the Effective Date has not occurred, NAPOCOR shall<br \/>\nreimburse and indemnify HOPEWELL for all costs and liabilities incurred by<br \/>\nHOPEWELL in respect of its obligations under Clause 3 provided that NAPOCOR has<br \/>\ngiven its prior written approval to HOPEWELL incurring such cost or liability;<br \/>\nNAPOCOR&#8217;s obligations under this Clause 7.05 shall be effective notwithstanding<br \/>\nthat the Effective Date has not occurred or that all or any of the conditions<br \/>\nprecedent set out in Clauses 7.01, 7.02, 7.03 and 7.04 have not been satisfied<br \/>\nor waived.<\/p>\n<p>7.06         In the event that the lease referred to in Clause 7.02(iv), or any<br \/>\nof the approvals, consents, registrations, exemptions or other rights, laws or<br \/>\nregulations referred to in Clause 7.02, 7.03 or the Ninth Schedule is<br \/>\nsubsequently terminated, withdrawn, rescinded or amended or any new required<br \/>\nextension, approval, consent or registration cannot be obtained and as a result<br \/>\nthereof the interest of HOPEWELL in the Site, the Project or the Power Station<br \/>\nand\/or HOPEWELL&#8217;s expectation of its economic return (net of tax or other<br \/>\nimposition) on its investment is materially reduced, prejudiced or otherwise<br \/>\nadversely affected (including, without limitation, any restriction on the<br \/>\nability to remit funds in dollars outside of the Philippines) then the parties<br \/>\nhereto shall meet and endeavour to agree on amendments to this Agreement and if<br \/>\nafter 60 days no such agreement has been reached the provisions of Clause 17.01<br \/>\nshall apply.<\/p>\n<p>7.07         NAPOCOR and HOPEWELL shall meet and jointly certify that this<br \/>\nAgreement is no longer conditional and that the Effective Date has occurred.<\/p>\n<p>7.08         If all the conditions set forth in Clauses 3.01, 7.01, 7.02, 7.03<br \/>\nand 7.04 hereof have not been satisfied as of 1st January, 1989, the parties<br \/>\nhereto shall meet and endeavour to agree a new effective date; if no agreement<br \/>\nis reached on or before 15th January, 1989, this Agreement shall, subject to<br \/>\nClause 7.05, be declared automatically cancelled (except as required in respect<br \/>\nof Clause 7.05) and the<\/p>\n<p>                                       12<\/p>\n<p>   16<\/p>\n<p>parties shall have no liability with respect to each other except as provided<br \/>\nin Clause 7.05.<\/p>\n<p>8.         Operation of the Power Station<\/p>\n<p>8.01       HOPEWELL shall, at its own cost, be responsible for the management,<br \/>\noperation, maintenance and repair of the Power Station during the Co-operation<br \/>\nPeriod and shall use its best endeavours to ensure that the Power Station is in<br \/>\ngood operating condition and capable of converting fuel supplied by NAPOCOR into<br \/>\nelectricity in a safe and stable manner within the Operating Parameters.<\/p>\n<p>8.02       Notwithstanding Clause 8.01, it is understood and agreed by NAPOCOR<br \/>\nthat in order to undertake necessary overhaul, maintenance, inspection and<br \/>\nrepair HOPEWELL shall be entitled to periods of Downtime as provided in the<br \/>\nSixth Schedule and, by not later than the Completion Date and each anniversary<br \/>\nthereof, the parties hereto shall agree an annual schedule for Downtime during<br \/>\nthe course of the succeeding year which shall be revised as provided in the<br \/>\nSixth Schedule.<\/p>\n<p>8.03       HOPEWELL undertakes that during the Co-operation Period, subject to<br \/>\nthe supply of the necessary fuel pursuant to Clause 9 and to the other<br \/>\nprovisions hereof, it will operate the Power Station to convert such fuel into<br \/>\nelectricity in accordance with Clause 10.<\/p>\n<p>8.04     In pursuance of its obligations under Clause 8.01 HOPEWELL shall have<br \/>\nfull right to:<\/p>\n<p>         (i)      enter into contracts for the supply of materials and<br \/>\n                  services, including, contracts with NAPOCOR;<\/p>\n<p>         (ii)     appoint and remove consultants and professional advisers;<\/p>\n<p>         (iii)    purchase replacement equipment;<\/p>\n<p>         (iv)     appoint, organise and direct staff, manage and supervise<br \/>\n                  the Power Station;<\/p>\n<p>         (v)      establish and maintain regular inspection, maintenance and<br \/>\n                  overhaul procedures; and<\/p>\n<p>         (iv)     do all other things necessary or desirable for the running of<br \/>\n                  the Power Station within the Operating Parameters.<\/p>\n<p>8.05         NAPOCOR shall ensure that all infrastructural requirements and<br \/>\nutilities necessary for the operation of the Power Station within the Operating<br \/>\nParameters are made available in a timely fashion and accordingly shall at its<br \/>\nown cost, inter alia:<\/p>\n<p>         (i)      ensure that there is provided to the Site water, electricity,<br \/>\n                  telephone, telex and fax as provided in Section VI of the<br \/>\n                  First Schedule the cost of the utilization of which) other<br \/>\n                  than electricity) and normal fees shall be for HOPEWELL&#8217;s<br \/>\n                  account; and<\/p>\n<p>                                       13<br \/>\n   17<\/p>\n<p>         (ii)     maintain and repair the Transmission Line to ensure that at<br \/>\n                  all times it is capable of operating within the<br \/>\n                  specifications set out in the Fifth Schedule.<\/p>\n<p>8.06         NAPOCOR and HOPEWELL shall, from time to time, meet and discuss and<br \/>\nagree safety guidelines for the operation of the Power Station within the<br \/>\nOperating Parameters and following such agreement HOPEWELL shall operate the<br \/>\nPower Station within such safety guidelines.<\/p>\n<p>8.07         HOPEWELL shall operate the Power Station in accordance with all<br \/>\nenvironmental and other Philippine and local laws and regulations in force as at<br \/>\nthe date of this Agreement and shall comply with any changes in such laws and<br \/>\nregulations and with any new laws and regulations provided that if to comply<br \/>\nwith such changes or new laws and regulations would:<\/p>\n<p>         (i)      result in the Power Station being unable to operate in<br \/>\n                  accordance with the Specifications or within the Operating<br \/>\n                  Parameters; or<\/p>\n<p>         (ii)     in the opinion of HOPEWELL, result in the interest of<br \/>\n                  HOPEWELL in the Site, the Project or the Power Station and\/or<br \/>\n                  HOPEWELL&#8217;s expectation of its economic return (net of tax or<br \/>\n                  other imposition) on its investment being materially reduced,<br \/>\n                  prejudiced or otherwise adversely affected,<\/p>\n<p>then the parties shall meet and endeavour to agree on amendments to this<br \/>\nAgreement and if after 60 days no such agreement has been reached the provisions<br \/>\nof Clause 17.01 shall apply.<\/p>\n<p>8.08         Availability will be determined by reference to Downtime calculated<br \/>\nas provided in the Sixth Schedule and the parties will agree an annual schedule<br \/>\nof Availability which shall be reviewed from time to time; in agreeing such<br \/>\nAvailability Schedule HOPEWELL shall take account of the requirements of NAPOCOR<br \/>\nbut in no event shall HOPEWELL be obliged to agree to Availability in excess of,<br \/>\nor at times other than, that permitted after taking account of Downtime.<\/p>\n<p>9.           Supply of Fuel<\/p>\n<p>9.01         Throughout the Co-operation Period NAPOCOR shall at all times<br \/>\nsupply and deliver all fuel and (except in the case of a Black Start) start up<br \/>\nelectricity required by HOPEWELL and necessary for the Power Station to generate<br \/>\nthe electricity required to be produced by it pursuant to Clause 10.<\/p>\n<p>9.02         The cost of the fuel to be supplied by NAPOCOR pursuant to Clause<br \/>\n9.01 shall be for NAPOCOR&#8217;s account.<\/p>\n<p>9.03         All fuel and start up electricity to be supplied by NAPOCOR shall<br \/>\nbe of the quality and supplied and delivered in the manner described in the<br \/>\nFourth Schedule.<\/p>\n<p>                                       14 <\/p>\n<p>   18<br \/>\n9.04     All fuel shall be tested as provided in the Fourth Schedule, and<br \/>\n         HOPEWELL shall, at all times, be entitled to reject any fuel if the<br \/>\n         results of any test relating to it show that it does not comply with<br \/>\n         the Fuel Specifications but NAPOCOR shall not have any liability to<br \/>\n         HOPEWELL for damage to the Power Station resulting from the fuel not<br \/>\n         complying with the Fuel Specifications.<\/p>\n<p>9.05     NAPOCOR shall ensure that at all times the necessary stocks as required<br \/>\n         by HOPEWELL are stored at adjacent to the Site or are available for<br \/>\n         immediate delivery to the Site.<\/p>\n<p>9.06     NAPOCOR and HOPEWELL shall enter into a fuel management agreement as<br \/>\n         further described in the Fourth Schedule pursuant to which HOPEWELL<br \/>\n         shall agree to manage, but shall have no responsibility for security in<br \/>\n         respect of the fuel of NAPOCOR which has been delivered to the off Site<br \/>\n         fuel tanks upon the terms and conditions therein appearing and subject<br \/>\n         to the payment by NAPOCOR of the fees therein provided.<\/p>\n<p>10.      SUPPLY OF ELECTRICITY<\/p>\n<p>10.01    Subject to NAPOCOR supplying the necessary fuel and start up<br \/>\n         electricity pursuant to Clause 9, HOPEWELL agrees to convert such fuel<br \/>\n         into electricity and NAPOCOR agrees to take all electricity requested<br \/>\n         by NAPOCOR in accordance with the procedures set out in the Sixth<br \/>\n         Schedule and the Operating Parameters set out in the Second Schedule.<\/p>\n<p>10.02    The quantities of electricity delivered to NAPOCOR by HOPEWELL from<br \/>\n         time to time shall be monitored, measured and recorded in accordance<br \/>\n         with the provisions of the Seventh Schedule.<\/p>\n<p>10.03    HOPEWELL shall notify NAPOCOR promptly of the occurrence of any event<br \/>\n         (other than scheduled Downtime) which results or may result in the<br \/>\n         Power Station being unable to operate in accordance with the<br \/>\n         Specifications and within the Operating Parameters.<\/p>\n<p>10.04    The place for delivery of the electricity shall be the Delivery Points.<\/p>\n<p>11.      FEES<\/p>\n<p>11.01    In respect of each Month from the Completion Date until and including<br \/>\n         the Month in which the Transfer Date falls NAPOCOR shall pay to<br \/>\n         HOPEWELL PHILIPPINES Capacity Fees, Energy Fees and Start Up Fees<br \/>\n         calculated as provided in the Eighth Schedule.<\/p>\n<p>11.02    In respect of each Month HOPEWELL will deliver to NAPOCOR an invoice in<br \/>\n         respect of Capacity Fees, Energy Fees and Start Up Fees for such Month<br \/>\n         and NAPOCOR shall pay to HOPEWELL the amount of such invoice within 30<br \/>\n         days after the delivery of such invoice.<\/p>\n<p>11.03    All fees payable to HOPEWELL pursuant to this Clause shall be paid<br \/>\n         together with Value Added Tax thereon (which shall be separately <\/p>\n<p>                                       15<br \/>\n   19<\/p>\n<p>stated in all invoices) in dollars in respect of the dollar portion and in<br \/>\npesos in respect of any pesos portion and each sum payable shall be increased<br \/>\nso as to ensure that after NAPOCOR has deducted therefrom any and all taxes or<br \/>\ncharges required to be deducted therefrom by NAPOCOR there remains a sum equal<br \/>\nto the amount that would have been payable to HOPEWELL had there been no<br \/>\nrequirement to deduct or withhold such taxes or other charges.<\/p>\n<p>11.04    NAPOCOR shall pay to HOPEWELL Energy Fees in respect of all<br \/>\nelectricity generated during commissioning and testing.<\/p>\n<p>11.05    NAPOCOR shall pay to HOPEWELL Energy Fees and Start Up Fees calculated<br \/>\nas provided in the Eighth Schedule in respect of any requested energy and<br \/>\nrequested start up prior to the start of the Co-operation Period.<\/p>\n<p>11.06    NAPOCOR shall pay HOPEWELL Capacity Fees calculated as provided in the<br \/>\nEighth Schedule in respect of the period, if any, from the Completion Date<br \/>\nuntil the Target Completion Date.<\/p>\n<p>11.07    In respect of each month, HOPEWELL will deliver to NAPOCOR an invoice<br \/>\nin respect of Capacity Fees, Energy Fees and Start Up Fees payable pursuant to<br \/>\nClauses 11.04, 11.05 or 11.06 for such month and NAPOCOR shall pay to HOPEWELL,<br \/>\nthe amount of such invoice within 30 days after the delivery of such notice.<\/p>\n<p>11.08    If any amount payable by NAPOCOR hereunder whether in respect of fees<br \/>\nor otherwise is not paid on or before the due date NAPOCOR shall pay interest<br \/>\nthereon, calculated at the rate of Prime plus 3% p.a. if the amount was due in<br \/>\ndollars and the T-Bill Rate plus 3% p.a. if the amount was due in pesos, from<br \/>\nthe date upon which it was due until the date upon which such amount is<br \/>\nreceived by HOPEWELL.<\/p>\n<p>11.09    All payments made by NAPOCOR hereunder shall be made free and clear of<br \/>\nand without any deduction for or on account of any set-off, counterclaim, tax<br \/>\nor otherwise except as required by law.<\/p>\n<p>11.10    If NAPOCOR disputes the amount specified in any invoice it shall so<br \/>\ninform HOPEWELL within seven (7) days of receipt of such invoice; if the<br \/>\ndispute is not resolved by the due date NAPOCOR shall pay the undisputed amount<br \/>\non or before such date and the disputed amount shall be resolved within<br \/>\nfourteen (14) days of the due date for such invoice and any sum paid to<br \/>\nHOPEWELL shall be paid together with interest pursuant to Clause 11.08 from the<br \/>\ndue date of such invoice.<\/p>\n<p>12.      FOREIGN EXCHANGE<\/p>\n<p>12.01    All sums payable to HOPEWELL in dollars shall be payable in dollars in<br \/>\nHong Kong, in same-day funds not later than 11:00 a.m., Hong Kong time, on the<br \/>\nday when payment is due, to the account of HOPEWELL (which HOPEWELL shall<br \/>\nnotify to NAPOCOR) at Citibank, N.A. of Citicorp Centre, 18 Whitfield Road,<br \/>\nCauseway Bay, Hong Kong or such other account as HOPEWELL may specify and is<br \/>\nacceptable to NAPOCOR.<\/p>\n<p>                                       16<br \/>\n   20<br \/>\n12.02    Any costs incurred by NAPOCOR in connection with the remittance of<br \/>\nfunds outside the Philippines may be deducted from the amount so remitted up to<br \/>\na maximum amount equal to 0.15% of the amount remitted, all other costs incurred<br \/>\nin making payments in accordance with the terms of this Agreement shall be for<br \/>\nNAPOCOR&#8217;s account.<\/p>\n<p>12.03    All sums payable to HOPEWELL in pesos shall be payable in pesos in<br \/>\nManila, in same-day funds not later than 11.00 a.m., Manila time, on the day<br \/>\nwhen payment is due, to the account of HOPEWELL with a bank in Manila that<br \/>\nHOPEWELL shall specify to NAPOCOR.<\/p>\n<p>12.04    In the event that any payment, whether pursuant to judgment or<br \/>\notherwise, upon prompt conversion to dollars and transfer to Hong Kong, as<br \/>\nprovided in Clause 12.01, does not result in payment of the dollar amount<br \/>\nstipulated in this Agreement, HOPEWELL shall be entitled to immediate payment<br \/>\nof, and shall have a separate cause of action, for the dollar deficiency.<\/p>\n<p>13.      INSURANCE<\/p>\n<p>         HOPEWELL shall be responsible to ensure there is effected insurance as<br \/>\nprovided in the Tenth Schedule.<\/p>\n<p>14.      TRANSFER OF OWNERSHIP<\/p>\n<p>14.01    On the Transfer Date HOPEWELL shall transfer to NAPOCOR, free from any<br \/>\nlien or encumbrance created by HOPEWELL and without the payment of any<br \/>\ncompensation, all its right, title and interest in and to the fixtures,<br \/>\nfittings, plant and equipment (including test equipment and special tools) and<br \/>\nall improvements comprising the Power Station.<\/p>\n<p>14.02    Six months prior to the Transfer Date, NAPOCOR and HOPEWELL shall meet<br \/>\nand agree the inventories involved, the mechanics of transfer and security<br \/>\narrangements but HOPEWELL shall not be liable for any discrepancies between such<br \/>\ninventories and the actual fixtures, fittings, plant and equipment transferred<br \/>\nprovided that following agreement on inventories HOPEWELL shall exercise the<br \/>\nsame care regarding the fixtures, fittings, plant and equipment and all<br \/>\nimprovements therein as it did prior to agreeing the same and provided further<br \/>\nthat NAPOCOR shall be entitled to provide a security unit within the Site.<\/p>\n<p>14.03    The Power Station and all other equipment transferred pursuant to this<br \/>\nClause 14 shall be transferred on an &#8220;as is&#8221; basis and any warranties which<br \/>\nwould otherwise be implied by statute or otherwise, including, without<br \/>\nlimitation, warranties as to title, fitness for the purpose, the absence of<br \/>\npatent or inherent defects, description or otherwise of whatsoever nature will<br \/>\nbe excluded and after the Transfer Date HOPEWELL shall be under no liability<br \/>\nwhatsoever to NAPOCOR in respect of the operation or otherwise of the Power<br \/>\nStation by NAPOCOR or a person designated by NAPOCOR and NAPOCOR shall indemnify<br \/>\nand keep indemnified HOPEWELL against any liability to any person arising from<\/p>\n<p>                                       17<br \/>\n   21<br \/>\nthe use or operation of the Power Station after the Transfer Date Provided<br \/>\nhowever that HOPEWELL shall subrogate or assign to NAPOCOR any and all rights<br \/>\nand benefits which it is able to subrogate or assign of any unexpired warranties<br \/>\nin respect of the building, plant and equipment of the Power Station under<br \/>\napplicable laws or otherwise.<\/p>\n<p>14.04    NAPOCOR shall be responsible for all costs and expenses (including<br \/>\nlegal fees and taxes or duties) incurred in connection with the transfer<br \/>\nreferred in this Clause 14 and shall at its own cost obtain or effect all<br \/>\ngovernmental and other approvals, licences, registrations and filings and take<br \/>\nsuch other action as may be necessary for the transfer contemplated in this<br \/>\nClause 14, and reimburse HOPEWELL on demand for all such costs and expenses<br \/>\nincurred by HOPEWELL in respect of such transfer.<\/p>\n<p>15.      LIABILITY<\/p>\n<p>15.01    In the event that, in breach of its obligations hereunder, HOPEWELL<br \/>\nfails to construct the Power Station, HOPEWELL shall reimburse and indemnify<br \/>\nNAPOCOR for all costs and liabilities incurred by NAPOCOR in respect of<br \/>\nNAPOCOR&#8217;s obligations under Clause 2 or Clause 3.<\/p>\n<p>15.02    HOPEWELL&#8217;s liability to NAPOCOR arising from any breach of this<br \/>\nAgreement or otherwise in connection with the design, construction and operation<br \/>\nof the Power Station shall be limited to payments as provided in Clauses 5.03,<br \/>\n5.04 and 15.01 and the penalties as provided in Sections 5.1 and 5.2 of the<br \/>\nEighth Schedule.<\/p>\n<p>15.03    NAPOCOR shall indemnify and hold HOPEWELL, its officers and employees<br \/>\nharmless against any claims of any person who directly or indirectly suffers as<br \/>\na result of an interruption of electricity supply or any other disruption or<br \/>\nsurge of electricity supply arising out of or in connection with this Agreement<br \/>\nand\/or the design, construction, equiping, testing, commissioning and\/or<br \/>\noperation of the Power Station and any of HOPEWELL&#8217;s, its officers&#8217; or<br \/>\nemployees&#8217; actions or omissions in connection with the same.<\/p>\n<p>15.04    Subject to Clause 15.03, HOPEWELL shall hold NAPOCOR, its officers and<br \/>\nemployees free of and harmless from any claims or suits of any third party,<br \/>\nother than claims for economic loss, arising from HOPEWELL&#8217;s operation of the<br \/>\nPower Station.<\/p>\n<p>15.05    Except where otherwise stated in this Agreement, the duties,<br \/>\nobligations and liabilities of the parties hereto are intended to be several and<br \/>\nnot joint or collective and nothing contained in this Agreement shall be<br \/>\nconstrued to create an association, trust, partnership or joint venture amongst<br \/>\nthe parties hereto and each party shall be liable individually and severally for<br \/>\nits own obligations under this Agreement.<\/p>\n<p>                                       18<br \/>\n   22<br \/>\n16.      FORCE MAJEURE<\/p>\n<p>16.01    No failure or omission to carry out or observe any of the terms,<br \/>\nprovisions or conditions of this Agreement shall give rise to any claim by any<br \/>\nparty hereto against any other party hereto, or be deemed to be breach of this<br \/>\nAgreement if the same shall be caused by or arise out of:<\/p>\n<p>         (a)      (other than as referred to in paragraph (b) below), any war,<br \/>\n                  declared or not or hostilities, or of belligerence, blockade,<br \/>\n                  revolution, insurrection, riot, public disorder,<br \/>\n                  expropriation, requisition, confiscation or nationalization,<br \/>\n                  export or import restrictions by any governmental authorities,<br \/>\n                  closing of harbours, docks, canals, or other assistances to or<br \/>\n                  adjuncts of the shipping or navigations of or within any<br \/>\n                  place, rationing or allocation, whether imposed by law, decree<br \/>\n                  or regulation by, or by compliance of industry at the<br \/>\n                  insistence of any governmental authority, or fire, unusual<br \/>\n                  flood, earthquake, storm, lightning, tide (other than normal<br \/>\n                  tides), tidal wave, perils of the sea, accidents of navigation<br \/>\n                  or breakdown or injury of vessels, accidents to harbours,<br \/>\n                  docks, canals, or other assistances to or adjuncts of the<br \/>\n                  shipping or navigation, epidemic, quarantine, strikes or<br \/>\n                  combination of workmen, lockouts or other labour disturbances,<br \/>\n                  or any other event, matter or thing, wherever occurring, which<br \/>\n                  shall not be within the reasonable control of the party<br \/>\n                  affected thereby; or<\/p>\n<p>         (b)      war, declared or not or hostilities involving the Republic of<br \/>\n                  the Philippines, or of belligerence, blockade, revolution,<br \/>\n                  insurrection, riot, public disorder, expropriation,<br \/>\n                  requisition, confiscation or nationalization by or involving<br \/>\n                  the Republic of the Philippines, export or import restrictions<br \/>\n                  by any governmental, regional or municipal authorities of or<br \/>\n                  within the Republic of the Philippines, closing of harbours,<br \/>\n                  docks, canals, or other assistances to or adjuncts of the<br \/>\n                  shipping or navigation of or within the Republic of the<br \/>\n                  Philippines, rationing or allocation, whether imposed by law,<br \/>\n                  decree or regulation by, or by compliance of industry at the<br \/>\n                  insistence of, any governmental authority of or within the<br \/>\n                  Republic of the Philippines, or any other event, matter or<br \/>\n                  thing, wherever occurring, which shall be within the<br \/>\n                  reasonable control of NAPOCOR or the government of the<br \/>\n                  Republic of the Philippines or any agency or regional of<br \/>\n                  municipal authority thereof,<\/p>\n<p>each of the foregoing event, matters or things being called &#8220;Force Majeure&#8221; in<br \/>\nthis Agreement.<\/p>\n<p>16.02    Notwithstanding Clause 16.01 NAPCOR (i) shall not be entitled to claim<br \/>\nfor itself Force Majeure in respect of any Force Majeure mentioned in<br \/>\nsub-paragraph (b) of Clause 16.01; and (ii) shall not be relieved of its<br \/>\nobligation to make payments of Capacity Fees as<\/p>\n<p>                                       19 <\/p>\n<p>   23<br \/>\nprovided in Clause 11.01 by the occurrence of any Force Majeure mentioned in<br \/>\nsub-paragraph (b) of Clause 16.01 whether affecting NAPOCOR or HOPEWELL.<\/p>\n<p>16.03    The party invoking Force Majeure shall:<\/p>\n<p>         (a)      notify the other parties as soon as reasonably possible by<br \/>\n                  telex or cable of the nature of the Force Majeure and the<br \/>\n                  extent to which the Force Majeure suspends the affected<br \/>\n                  party&#8217;s obligations under this Agreement; and<\/p>\n<p>         (b)      resume performance of its obligations as soon as possible<br \/>\n                  after the Force Majeure condition no longer exists.<\/p>\n<p>16.04    If Force Majeure applies prior to the Completion Date the parties will<br \/>\nmeet to discuss a revised timetable for the completion of the Project and if the<br \/>\nForce Majeure has applied for a period in excess of 180 days and such Force<br \/>\nMajeure is mentioned in sub-paragraph (b) of Clause 16.01 the provisions of<br \/>\nClause 17.01 shall apply.<\/p>\n<p>16.05    If Force Majeure applies by the occurrence of any Force Majeure<br \/>\nmentioned in sub-paragraph (a) of Clause 16.01 during the Co-operation Period<br \/>\nthe Co-operation Period shall be extended by a period equal to that during which<br \/>\nthe effect of the Force Majeure applies provided that if such effect applies for<br \/>\na period in excess of 180 days the parties hereto will meet to discuss the basis<br \/>\nand terms upon which the arrangements set out in this Agreement may be<br \/>\ncontinued.<\/p>\n<p>16.06    The parties hereto will consult with each other and take all reasonable<br \/>\nsteps to minimize the losses of either party resulting from Force Majeure.<\/p>\n<p>16.07    If any event of Force Majeure occurs which causes damage to the Project<br \/>\nor the Power Station and such event or such damage would not ordinarily be<br \/>\ninsured against by NAPOCOR then HOPEWELL shall not be obliged to reinstate the<br \/>\nPower Station, or, as the case may be, complete the building of the same, until<br \/>\nthe parties hereto have agreed upon the terms for such reinstatement or<br \/>\ncompletion.<\/p>\n<p>17.      BUYOUT<\/p>\n<p>17.01    If the circumstances set out in Clause 7.06, Clause 8.07, Clause 16.04,<br \/>\nClause 16.07 or Clause 18 arise or if, not earlier than 5 years after the<br \/>\nCompletion Date, NAPOCOR gives not less than 90 days notice to HOPEWELL that<br \/>\neither it wishes to close the Power Station or it wishes to move the gas<br \/>\nturbines to elsewhere in the Philippines or if, NAPOCOR has failed to ensure the<br \/>\ndue payment of any sum due hereunder within three months of its due date then,<br \/>\nupon HOPEWELL giving to NAPOCOR not less than 90 days notice requiring NAPOCOR<br \/>\nto buyout HOPEWELL or, as the case may be, NAPOCOR giving not less than 90 days<br \/>\nnotice requiring HOPEWELL to sell out to NAPOCOR, NAPOCOR shall purchase all<br \/>\nHOPEWELL&#8217;s right, title and interest in and to the Power Station and thereupon<br \/>\nall HOPEWELL&#8217;s obligations hereunder shall cease.<\/p>\n<p>                                       20<br \/>\n   24<\/p>\n<p>17.02    In respect of any transfer of the Power Station pursuant to Clause<br \/>\n17.01 the provisions of Clause 14 (other than Clauses 14.01 and 14.02) shall<br \/>\napply thereto.<\/p>\n<p>17.03    Subject to Clause 17.04, the purchase price in dollars, payable<br \/>\npursuant to Clause 17.01 will be the total amount of the Capacity Fees payable<br \/>\nto HOPEWELL pursuant to Clause 11.01 until the Transfer Date upon the<br \/>\nassumption that the Contracted Capacity during each year of the Co-operation<br \/>\nPeriod for such period is equal to the lower of the Contracted Capacity last<br \/>\nnominated by HOPEWELL and the Nominal Capacity and the resulting figure<br \/>\ndiscounted to its value on the date of completion of the buyout by applying a<br \/>\ndiscount rate equal to the last published Commercial Interest Reference Rate<br \/>\nfor dollars published by the Organization for Economic Cooperation and<br \/>\nDevelopment Provided that no buyout may take place without the consent of<br \/>\nHOPEWELL if the purchase price calculated as above is not positive.<\/p>\n<p>17.04    If the provision of Clause 17.01 apply prior to the Completion Date,<br \/>\nthe purchase price payable shall be an amount equal to the aggregate of all<br \/>\nthe costs, expenses and liabilities incurred by HOPEWELL in connection herewith<br \/>\nas estimated by an independent accountant jointly appointed by both parties and<br \/>\nsubject to a maximum amount of $42,000,000 plus an amount equal to ten percent<br \/>\n(10%) of such aggregate provided such additional amount shall not be payable if<br \/>\nthe provisions of Clause 17.01 are applicable pursuant to Clause 16.04.<\/p>\n<p>17.05    Completion of a buyout pursuant to Clause 17.01 shall take place on<br \/>\nthe date of the expiry of the notice specified therein at which time NAPOCOR<br \/>\nwill pay to HOPEWELL the purchase price calculated in accordance with Clause<br \/>\n17.03 or, as the case may be, Clause 17.04 and payable in dollars and HOPEWELL<br \/>\nshall warrant that following such buyout the Power Station shall be free from<br \/>\nany lien or encumbrance created by HOPEWELL.<\/p>\n<p>17.06    In the event that the provisions of Clause 17.01 apply pursuant to<br \/>\nClause 16.04 then there shall be deducted from the sum payable pursuant to<br \/>\nClause 17.04 an amount equal to the value, if any, of any insurance proceeds<br \/>\nreceived by HOPEWELL in respect of the event leading to the operation of the<br \/>\nprovisions of Clause 16.04.<\/p>\n<p>18.      CHANGE IN CIRCUMSTANCES<\/p>\n<p>         In the event that as a result of any laws or regulations of the<br \/>\nRepublic of the Philippines, or any agency or other body under the control of<br \/>\nthe Government of the Republic of the Philippines or any regional or municipal<br \/>\nauthority thereof, coming into effect after the date hereof, or as a result of<br \/>\nany such laws or regulations (including any official interpretation thereof<br \/>\nwhich HOPEWELL has relied upon in entering into this Agreement) in force at the<br \/>\ndate hereof being amended, modified or repealed, the interest of HOPEWELL in<br \/>\nthe Site, the Project or the Power Station and\/or HOPEWELL&#8217;s expectation of its<br \/>\neconomic return (net of tax or other imposition) on its investment is<br \/>\nmaterially reduced, prejudiced or otherwise adversely affected (including,<br \/>\nwithout limitation, any restriction on the ability to <\/p>\n<p>                                       21<br \/>\n   25<br \/>\nremit funds in dollars outside of the Philippines) then the parties hereto<br \/>\nshall meet and endeavour to agree amendments to this Agreement and if after 90<br \/>\ndays no such agreement has been reached the provisions of Clause 17.01 shall<br \/>\napply.<\/p>\n<p>19.      Benefit of Agreement<\/p>\n<p>19.01    NAPOCOR may not assign or transfer all or any part of its rights,<br \/>\nbenefits or obligations hereunder Provided that this Clause shall not prevent<br \/>\nNAPOCOR from merging or consolidating with any other company which is wholly<br \/>\nowned by the Republic of the Philippines where the surviving entity adopts and<br \/>\nbecomes fully liable to perform NAPOCOR&#8217;s obligations hereunder.<\/p>\n<p>19.02    HOPEWELL may not, subject to Clause 19.03, transfer all or any of its<br \/>\nobligations hereunder but may, for the purposes of arranging or rearranging<br \/>\nfinance for the Project, assign or transfer to any person providing finance to<br \/>\nthe Project all or any part of its rights and benefits hereunder but not its<br \/>\nobligations and NAPOCOR shall duly acknowledge any such assignment or transfer<br \/>\nof which it is given notice.<\/p>\n<p>19.03    The importation into the Philippines of all equipment for the Project<br \/>\nand all other work in connection with the Project which necessarily has to be<br \/>\nperformed in the Philippines and which HOPEWELL agrees to be responsible for<br \/>\nhereunder shall be carried out by HOPEWELL PHILIPPINES which shall undertake to<br \/>\nperform HOPEWELL&#8217;s obligations to perform such work and in consideration of<br \/>\nwhich NAPOCOR shall pay fees as provided in Clause 11; HOPEWELL PHILIPPINES, in<br \/>\ncarrying out such work and receiving such fees shall act on its own behalf and<br \/>\nfor its own benefit, and not as an agent or representative of HOPEWELL. For such<br \/>\npurpose, HOPEWELL, NAPOCOR and HOPEWELL PHILIPPINES (whose participation<br \/>\nHOPEWELL shall procure) shall execute and deliver the Accession Undertaking,<br \/>\nupon the effectiveness of which HOPEWELL PHILIPPINES shall become a party hereto<br \/>\nwithout the need for any further action on the part of HOPEWELL or NAPOCOR and<br \/>\nthe rights and obligations of NAPOCOR and HOPEWELL under this Agreement shall be<br \/>\ntransferred and amended in accordance with the terms of the Accession<br \/>\nUndertaking, as if HOPEWELL PHILIPPINES had executed this Agreement as amended<br \/>\nby the terms of the Accession Undertaking.<\/p>\n<p>20.      Warranty<\/p>\n<p>         HOPEWELL hereby warrants that neither it nor its representatives have<br \/>\noffered any government officer and\/or NAPOCOR official or employee any<br \/>\nconsideration or commission for this Agreement nor has it or its representatives<br \/>\nexerted or utilized any corrupt or unlawful influence to secure or solicit this<br \/>\nAgreement for any consideration or commission; that HOPEWELL shall not<br \/>\nsubcontract any portion or portions of the scope of the work of the Agreement<br \/>\nawarded to any official or employee of NAPOCOR or to the relatives within the<br \/>\nthird degree of consanquinity or affinity of NAPOCOR officials who are directly<br \/>\nor indirectly involved in contract awards<\/p>\n<p>                                       22<br \/>\n   26<br \/>\nor project prosecution and that if any commission is being paid to a private<br \/>\nperson, HOPEWELL shall disclose the name of the person and the amount being paid<br \/>\nand that any violation of this warranty shall constitute a sufficient ground for<br \/>\nthe recission or cancellation of this Agreement or the deduction from the<br \/>\ncontract price of the consideration or commission paid without prejudice to the<br \/>\nfiling of civil or criminal action under the Anti-Graft Law and other applicable<br \/>\nlaws against HOPEWELL and\/or its representatives and NAPOCOR&#8217;s officials and<br \/>\nemployees.<\/p>\n<p>21.      NOTICES<\/p>\n<p>21.01    Unless otherwise stated, each communication to be made hereunder shall<br \/>\nbe made in writing but, unless otherwise stated, may be made by telex or letter.<\/p>\n<p>21.02    Any communication or document to be made or delivered by one party to<br \/>\nanother pursuant to this Agreement shall be made or delivered to that other at<br \/>\nits address specified above or such other address notified by that party to the<br \/>\nother parties by giving not less than 15 days notice of such change of address,<br \/>\nand shall be deemed to have been made or delivered (i) in the case of any<br \/>\ncommunication made by telex with correct answerback (at the number identified<br \/>\nwith the relevant party&#8217;s signature below), when despatched, and (ii) in the<br \/>\ncase of any communication made by letter, when left at that address or otherwise<br \/>\nreceived by the addressee.<\/p>\n<p>22.      DISPUTE RESOLUTION<\/p>\n<p>22.01    Throughout the term of this Agreement representatives of the Directors<br \/>\nof NAPOCOR, Hopewell Holdings Limited, HOPEWELL and Hopewell Philippines shall<br \/>\nmeet regularly at not less than yearly intervals to discuss the progress of the<br \/>\nProject and the operation of the Power Station in order to ensure that the<br \/>\narrangements between the parties hereto proceed on a mutually satisfactory<br \/>\nbasis.<\/p>\n<p>22.02    The parties hereto agree that in the event that there is any dispute or<br \/>\ndifference between them arising out of this Agreement or in the interpretation<br \/>\nof any of the provisions hereof they shall endeavour to meet together in an<br \/>\neffort to resolve such dispute by discussion between them but failing such<br \/>\nresolution the Chief Executives of Hopewell Holdings Limited and NAPOCOR shall<br \/>\nmeet to resolve such dispute or difference and the joint decision of such Chief<br \/>\nExecutives shall be binding upon the parties hereto and in the event that a<br \/>\nsettlement of any such dispute or difference is not reached pursuant to this<br \/>\nsub-clause then the provisions of Clause 24 shall apply.<\/p>\n<p>23.      LAW<\/p>\n<p>         This Agreement shall be governed by and construed in accordance with<br \/>\nthe laws of the Republic of the Philippines.<\/p>\n<p>                                       23<br \/>\n   27<\/p>\n<p>24.      Jurisdiction<\/p>\n<p>24.01    The parties hereto submit to the non-exclusive jurisdiction of the<br \/>\nproper courts of the Republic of the Philippines for the hearing and<br \/>\ndetermining of any action or proceeding arising out of or in connection with<br \/>\nthis Agreement.<\/p>\n<p>24.02    To the extent that NAPOCOR may in any jurisdiction claim for itself or<br \/>\nits assets or revenues immunity from suit, execution, attachment (whether in<br \/>\naid of execution, before judgment or otherwise) or other legal process and to<br \/>\nthe extent that in any such jurisdiction there may be attributed to itself or<br \/>\nits assets or revenues such immunity (whether or not claimed) NAPOCOR agrees<br \/>\nnot to claim and irrevocably waives such immunity to the full extent permitted<br \/>\nby the laws of such jurisdiction.<\/p>\n<p>AS WITNESS the hands of the duly authorised representatives of the parties<br \/>\nhereto on the Sixteenth day of November in the year nineteen hundred and eighty<br \/>\neight.<\/p>\n<p>                                       24 <\/p>\n<p>   28<br \/>\n                                 FIRST SCHEDULE<\/p>\n<p>                        PROJECT SCOPE AND SPECIFICATIONS<\/p>\n<p>I.       Scope of Agreement<\/p>\n<p>         HOPEWELL shall be responsible for the design, supply, delivery,<br \/>\ninstallation\/erection including civil works, testing and commissioning of a gas<br \/>\nturbine power station.<\/p>\n<p>II.      The Site<\/p>\n<p>         The Site is located at the Navotas Fishing Complex to the North of<br \/>\nCentral Manila. A minimum of 1.88 hectares of land will be made available for<br \/>\nthe Power Station as shown in figure 1 attached plus an additional area of 0.66<br \/>\nhectares.<\/p>\n<p>         Access to the Site will be from the fishing port road and a heavy road<br \/>\naccess shall be provided to the waterfront.<\/p>\n<p>         NAPOCOR will clear and prepare the Site for occupation and give<br \/>\nHOPEWELL vacant possession. Overhead distribution electricity lines currently<br \/>\nrunning across the Site will be relocated off the Site by NAPOCOR and NAPOCOR<br \/>\nwill erect a temporary fence around the perimeter as shown in figure 2 attached.<\/p>\n<p>III.     Extent of Works\/Supply<\/p>\n<p>         In pursuance to its obligations under Section I; HOPEWELL shall be<br \/>\nresponsible for:<\/p>\n<p>         1.       Complete design, development and construction on the Site of<br \/>\n                  the Power Station, with Black Start Up capability, based on<br \/>\n                  the final mix of turbine units decided upon by HOPEWELL.<\/p>\n<p>         2.       Civil Works<\/p>\n<p>                  2.1      Site development including grading, gravel surfacing<br \/>\n                           and drainage facilities.<\/p>\n<p>                  2.2      Construction of concrete foundations.<\/p>\n<p>                  2.3      Construction of access road within the Site and<br \/>\n                           permanent fence around the Site and the tank farm.<\/p>\n<p>                  2.4      Construction of cable trenches.<\/p>\n<p>                  2.5      Pile driving.<\/p>\n<p>                                       25<br \/>\n   29<br \/>\n                  2.6      Construction of office, laboratory, workshops,<br \/>\n                           storehouses.<\/p>\n<p>                  2.7      Construction of an oil\/water separator and a septic<br \/>\n                           tank.<\/p>\n<p>         3.       ELECTRO-MECHANICAL WORKS<\/p>\n<p>                  Supply, installation\/erection, tests and commissioning to put<br \/>\n                  into operation the required number of generation units and its<br \/>\n                  corresponding minimum gross aggregate capacity of 200 MW<br \/>\n                  (subject to the provisions of Clause 5.05).<\/p>\n<p>                  3.1      Gas turbine packages, with two generating units<br \/>\n                           having a Black Start capability of their own,<br \/>\n                           consisting of the turbine, compressor, combustor and<br \/>\n                           its auxiliaries, including air intake system, exhaust<br \/>\n                           gas system, cooling system, lubricating oil system,<br \/>\n                           fuel oil system, starting system.<\/p>\n<p>                  3.2      Generator package, complete with necessary equipment<br \/>\n                           and accessories.<\/p>\n<p>                  3.3      Electrical equipment; including main and auxiliary<br \/>\n                           transformers; metal clad switchgear, control<br \/>\n                           switchboard; motor control centre, including control<br \/>\n                           panels, direct current system complete with battery<br \/>\n                           charger, inverters; required high voltage equipment<br \/>\n                           devices and accessories including necessary cables<br \/>\n                           and hardwares for interconnection to the proposed 115<br \/>\n                           KV switchyard; metering and line protection<br \/>\n                           compatible with the existing Meralco system (which<br \/>\n                           will be notified to HOPEWELL prior to the Effective<br \/>\n                           Date), as shown in figure 3 attached.<\/p>\n<p>                  3.4      The extent of the work and supply of HOPEWELL<br \/>\n                           pursuant to 3.3 shall be in accordance with figure 4<br \/>\n                           attached.<\/p>\n<p>                  3.5      Required instrumentation indicators, protection,<br \/>\n                           control and automation of gas turbine units and their<br \/>\n                           auxiliaries, complete with necessary supervisory<br \/>\n                           devices, electronic modules for control and<br \/>\n                           protection, data acquisition system, for safe and<br \/>\n                           reliable operation of the Power Station.<\/p>\n<p>                  3.6      Air conditioning system for the protection of<br \/>\n                           electrical equipment and instruments at the local<br \/>\n                           control room.<\/p>\n<p>                  3.7      Fire protection and alarm systems.<\/p>\n<p>                  3.8      Instrument air system (if necessary).<\/p>\n<p>                  3.9      Handling facilities for maintenance and repair.<\/p>\n<p>                                        26<\/p>\n<p>   30<\/p>\n<p>                  3.10     Miscellaneous electrical works, including lighting,<br \/>\n                           grounding and lightning protection.<\/p>\n<p>                  3.11     Voice and data communication systems in accordance<br \/>\n                           with figure 5 attached inside the Power Station and<br \/>\n                           to and from NAPOCOR Power Management Center details<br \/>\n                           of which will be notified to HOPEWELL prior to the<br \/>\n                           Effective Date.<\/p>\n<p>                  3.12     Fuel oil valve and piping system and metering as<br \/>\n                           shown in figure 6 attached.<\/p>\n<p>                  3.13     Water tank, hydrant and piping systems.<\/p>\n<p>                  3.14     Special tools.<\/p>\n<p>IV.      DESIGN CRITERIA<\/p>\n<p>         1.       Gas Turbine Units<\/p>\n<p>                  The gas turbine units, two of which with Black Start<br \/>\n                  capability of their own, and with an aggregate capacity of not<br \/>\n                  less than 200 MW (subject to the provisions of Clause 5.05)<br \/>\n                  shall be capable of delivering the said output at the<br \/>\n                  following Site conditions:<\/p>\n<table>\n                  <s>   <c>                              <c> <c><br \/>\n                  1.1   Elevation (Above Mean Sea Level) &#8211;   2.0 meters<br \/>\n                  1.2   Ambient air temperature          &#8211;   37 (degrees) Centigrade<br \/>\n                  1.3   Relative humidity                &#8211;   85%<br \/>\n                  1.4   Temp. range                      &#8211;   18-37 (degrees) Centigrade<br \/>\n                  1.5   Noise level                      &#8211;   to comply with NPCC<br \/>\n                                                             Regulation No. 4479 dated<br \/>\n                                                             5th June, 1978<br \/>\n<\/c><\/c><\/c><\/s><\/table>\n<p>         2.       Heat Rates<\/p>\n<p>                  The guaranteed heat rate shall be based on the net kilowatt<br \/>\n                  output for the conditions specified in paragraph 1 of Section<br \/>\n                  IV above and the Lower Heating Value of the fuel as specified<br \/>\n                  in the Fourth Schedule.<\/p>\n<p>         3.       Fuel<\/p>\n<p>                  Fuel specifications will be in accordance with the Fourth<br \/>\n                  Schedule.<\/p>\n<p>                                       27 <\/p>\n<p>   31<br \/>\n         4.       System Fault Level<\/p>\n<p>                  The present 110 KV bus fault level when the gas turbine units<br \/>\n                  are connected in the Luzon Grid shall be as follows:<\/p>\n<p>                  4.1      Line to ground fault       :        5,100 MVA<\/p>\n<p>                  4.2      3-phase fault              :        5,000 MVA<\/p>\n<p>                  4.3      Interrupting Capacity<br \/>\n                           at 110 KV                  :        40 KA<\/p>\n<p>         5.       System Voltage Level<\/p>\n<p>                  5.1      Generator terminal voltage :        13.8 KV +\/- 5%<\/p>\n<p>                  5.2      Main transformer:<\/p>\n<p>                             High Voltage (Nominal)   :        110 KV<\/p>\n<p>                             Off Load Tap Change      :        105\/110\/115 KV<\/p>\n<p>                             Low Voltage              :        13.4 KV<\/p>\n<p>                  5.3      Nominal voltage for auxiliary equipment (for<br \/>\n                           information purposes)<\/p>\n<p>                           AC System         :        3.45 KV, 460 V and 230<br \/>\n                                                      Volts<\/p>\n<p>                           DC System         :        125 V, 48 V and 24 Volts<\/p>\n<p>         6.       System Frequency:                   60 Hertz<\/p>\n<p>         7.       Generator and Accessories<\/p>\n<p>                  The generator shall be designed to match the gas turbine units<br \/>\n                  to assume base and peak operating modes. The design<br \/>\n                  characteristics shall be as follows:<\/p>\n<p>                  7.1      Nominal MVA power output at rated power factor,<br \/>\n                           20(degrees) C ambient temperature, 75 MVA<\/p>\n<p>                  7.2      Three phase wye grounded, through resistance<\/p>\n<p>                  7.3      Rated terminal voltage     :        13.8 KV +\/- 5%<\/p>\n<p>                  7.4      Rated power factor         :        0.9 lagging<\/p>\n<p>                  7.5      Short circuit ratio (saturated)<\/p>\n<p>                           The measured value of the short circuit ratio at<br \/>\n                           rated MVA and rated voltage shall be not less than<br \/>\n                           0.47.<\/p>\n<p>                  7.6      Allowable voltage variations<\/p>\n<p>                           At rated MVA, frequency, power factor and inlet air<br \/>\n                           temperature, the turbine-generator can operate<br \/>\n                           satisfactorily even though the terminal voltage may<br \/>\n                           vary +\/- 5% operated value.<\/p>\n<p>                                       28<\/p>\n<p>   32<br \/>\nV.       Utilities During Construction Period<\/p>\n<table>\n<caption>\n                  Requirements                        Time of Supply<br \/>\n                  &#8212;&#8212;&#8212;&#8212;                        &#8212;&#8212;&#8212;&#8212;&#8211;<br \/>\n         <s>                                       <c><br \/>\n         Electricity &#8211; 750 KW                      By 15 days after the<br \/>\n           3 Phase Supply 220 V                       Effective Date<\/p>\n<p>         Water &#8211; 12,000 Litres                     By 15 days after the<br \/>\n                 per day                              Effective Date<br \/>\n           Fresh potable quality<\/p>\n<p>         Telephone  )                              By 15 days after the<br \/>\n           Fax      )      3 I.D.D. Lines             Effective Date<br \/>\n           Telex    )<br \/>\n<\/c><\/s><\/caption>\n<\/table>\n<p>VI.      Utilities During Co-operation Period<\/p>\n<table>\n<caption>\n                  Requirements                        Time of Supply<br \/>\n                  &#8212;&#8212;&#8212;&#8212;                        &#8212;&#8212;&#8212;&#8212;&#8211;<br \/>\n         <s>                                       <c><br \/>\n         Water &#8211; 20 Litres per second                   Throughout<br \/>\n           Fresh potable quality                   Co-operation Period<\/p>\n<p>         Telephone  )                                   Throughout<br \/>\n           Fax      )      3 I.D.D. Lines          Co-operation Period<br \/>\n           Telex    )<\/p>\n<p>         Sewage piping and storm drains                 Throughout<br \/>\n           from the side of the perimeter          Co-operation Period<br \/>\n           fence nearest to the sea.<br \/>\n<\/c><\/s><\/caption>\n<\/table>\n<p>                                       29<br \/>\n   33<\/p>\n<p>                                SECOND SCHEDULE<\/p>\n<p>                              OPERATING PARAMETERS<\/p>\n<p>A.       Operating Parameters<\/p>\n<p>         HOPEWELL shall operate the Power Station in accordance with the<br \/>\noperating criteria and guidelines of NAPOCOR. HOPEWELL shall cooperate with<br \/>\nNAPOCOR in establishing emergency plans including but not limited to recovery<br \/>\nfrom a local or widespread electrical blackout; voltage reduction to effect<br \/>\nload curtailment and other plans which may arise. HOPEWELL shall make technical<br \/>\nreferences available concerning start-up times, Black Start capabilities, and<br \/>\nminimum load carrying ability, broken down into:<\/p>\n<p>         1.       Capacity<\/p>\n<p>                  Subject to the provisions of Clause 5.05, the capacity of the<br \/>\n                  Power Station shall not be less than 200MW at 37 (degrees) C<br \/>\n                  site conditions, as measured at the generator terminals.<\/p>\n<p>         2.       Frequency Limitation<\/p>\n<p>                  The frequency limitations of gas turbine set for continuous<br \/>\n                  operation shall be between the range of 58.2 Hz and 61.5 Hz.<\/p>\n<p>                  The under frequency tripping relay shall be set at 57.5 Hz.<\/p>\n<p>                  The gas turbine overspeed trip shall be set at 19% above<br \/>\n                  normal speed.<\/p>\n<p>         3.       Normal Voltage<\/p>\n<p>                  The normal voltage at the high side of the main power<br \/>\n                  transformer shall be 110 KV, plus or minus 5 percent.<\/p>\n<p>         4.       Load Sharing Operation<\/p>\n<p>                  The units shall operate satisfactorily and without structural<br \/>\n                  damage in daily load sharing from 100 per cent of the<br \/>\n                  Contracted Capacity to the minimum capacity of the units<br \/>\n                  depending on the dispatch requirements of NAPOCOR Power<br \/>\n                  Management Center.<\/p>\n<p>         5.       Range and Ratio of Load Changing<\/p>\n<p>                  At normal operation mode, except during start up and shut<br \/>\n                  down, the generating units shall be capable of being operated<br \/>\n                  as follows:<\/p>\n<p>                                       30 <\/p>\n<p>   34<\/p>\n<p>                  &#8211;        Turbine preparation and    :        15 minutes per<br \/>\n                           start up to synchronous             unit<br \/>\n                           speed not less than<\/p>\n<p>                  &#8211;        Synchronizing and loading  :        4 MW per minute<br \/>\n                           to full load under normal<br \/>\n                           condition, ramp increase<br \/>\n                           not greater than<\/p>\n<p>                  In Emergency, the generating units shall be capable of being<br \/>\n                  operated as follows:<\/p>\n<p>                  &#8211;        Turbine preparation and    :        8 minutes per<br \/>\n                           start up to synchronous             unit<br \/>\n                           speed<\/p>\n<p>                  &#8211;        Synchronizing and loading  :        12 MW per minute<br \/>\n                           to full load under normal<br \/>\n                           condition, ramp increase<br \/>\n                           not greater than<\/p>\n<p>         6.       OPERATION MODE<\/p>\n<p>                  The Power Station shall be utilized as a peaking plant and be<br \/>\n                  expected to operate five (5) days per week &#8211; Monday to Friday<br \/>\n                  &#8211; and shall remain on standby over the weekend and during the<br \/>\n                  ten (10) public holidays per year, except during scheduled<br \/>\n                  maintenance. The Power Station however, is expected to<br \/>\n                  operate at any other time as may be called upon by NAPOCOR<br \/>\n                  during Emergency and\/or abnormal system conditions with<br \/>\n                  adequate notice having been given by NAPOCOR and would be<br \/>\n                  manned 24 hours a day.<\/p>\n<p>         7.       VARIATION OF POWER LOAD<\/p>\n<p>                  At any given load, it is estimated that the allowable load<br \/>\n                  change per unit should be not more than 4 MW per minute.<\/p>\n<p>         8.       EMERGENCY STARTS<\/p>\n<p>                  It is estimated that 10 minutes notice should be given for an<br \/>\n                  emergency start during which the loading rates should be<br \/>\n                  restricted to those shown in item 5.<\/p>\n<p>         9.       HEAT RATES<\/p>\n<p>                  Subject to the provisions of Clause 5.05, the net heat rate<br \/>\n                  of the Power Station following completion shall not be<br \/>\n                  greater than 12,300 BTU\/KWH reckoned at full load condition<br \/>\n                  in accordance with the Guarantee Tests described in the<br \/>\n                  Fourteenth Schedule. The Power Station will be tested to<br \/>\n                  establish the Guaranteed Plant Net Heat Rate of 12,300<br \/>\n                  BTU\/KWH. If results of the Guarantee Tests show a plant net<br \/>\n                  heat rate greater than 12,300 BTU\/KWH then HOPEWELL shall<br \/>\n                  endeavour to refurbish or rehabilitate the units or to<\/p>\n<p>                                       31<\/p>\n<p>   35<br \/>\n                  otherwise correct the units in order to achieve the Guaranteed<br \/>\n                  Plant Net Heat Rate. NAPOCOR shall not be obliged to pay the<br \/>\n                  Capacity and Energy fees for such period that the Tested Plant<br \/>\n                  Net Heat Rate at maximum continuous rating is equal to or more<br \/>\n                  than 13,500 BTU\/KWH except as permitted below (including<br \/>\n                  permitted tolerances). In the event that the Tested Plant Net<br \/>\n                  Heat Rate exceeds 12,300 BTU\/KWH at commissioning and Hopewell<br \/>\n                  declares the Power Station to be complete, then the<br \/>\n                  application of Section 5.2 Energy Fees of the Eighth Schedule<br \/>\n                  shall be based on the Tested Plant Net Heat Rate for such<br \/>\n                  period as HOPEWELL is unable to correct the Plant Net Heat<br \/>\n                  Rate.<\/p>\n<p>                  The permitted step increase in the Guaranteed Plant Net Heat<br \/>\n                  Rate shall be no greater than 73.8 BTU\/KWH after the lapse of<br \/>\n                  every average 6,000 EOH of the units up to 30,000 EOH and 123<br \/>\n                  BTU\/KWH per every average 6,000 EOH thereafter. Prior to the<br \/>\n                  Completion Date the parties hereto shall agree on the dates,<br \/>\n                  time and duration for the Guarantee Tests in accordance with<br \/>\n                  the Fourteenth Schedule.<\/p>\n<p>B.       OPERATING PROCEDURES<\/p>\n<p>         1.       DISPATCH PROCEDURE.  HOPEWELL shall control and operate the<br \/>\n                  Power Station consistent with NAPOCOR&#8217;s systems dispatch<br \/>\n                  requirements.<\/p>\n<p>         2.       ENGINEERING STANDARDS.  The Power Station including, but not<br \/>\n                  limited to, the protective apparatus shall be operated and<br \/>\n                  maintained in accordance with good engineering practices in<br \/>\n                  respect of synchronizing, voltage and reactive power control.<\/p>\n<p>         3.       PROTECTIVE DEVICES.  The Power Station shall be operated with<br \/>\n                  all of its protective apparatus in service whenever the<br \/>\n                  facility is connected to or is operated in parallel with the<br \/>\n                  NAPOCOR electric system. Any deviation for brief periods of<br \/>\n                  emergency or maintenance shall only be by mutual agreement.<\/p>\n<p>         4.       INTEGRITY LOSS.  If, at any time, NAPOCOR has reason to doubt<br \/>\n                  the integrity of any HOPEWELL protective apparatus and<br \/>\n                  suspects that such loss of integrity could jeopardise the<br \/>\n                  NAPOCOR electric system, HOPEWELL shall demonstrate, to<br \/>\n                  NAPOCOR&#8217;s satisfaction, the correct calibration and operation<br \/>\n                  of the equipment in question.<\/p>\n<p>         5.       TESTING OF PROTECTIVE DEVICES.  HOPEWELL shall test all<br \/>\n                  protective devices with qualified personnel at intervals not<br \/>\n                  to exceed one (1) year.<\/p>\n<p>         6.       NOTICE OF TESTS.  HOPEWELL shall notify NAPOCOR at least<br \/>\n                  fourteen (14) calendar days prior to: (1) the initial parallel<br \/>\n                  operation of each HOPEWELL generator and (2) testing of all<br \/>\n                  protective apparatus. NAPOCOR shall have the right to have a<br \/>\n                  representative present at such times.<\/p>\n<p>                                       32<br \/>\n   36<br \/>\n         7.       SERVICE COMMITMENT. At NAPOCOR&#8217;s request, HOPEWELL shall make<br \/>\n                  all reasonable efforts to deliver power during periods of<br \/>\n                  Emergency.<\/p>\n<p>         8.       MAINTENANCE DURING EMERGENCY. In the event that HOPEWELL&#8217;s<br \/>\n                  scheduled Downtime coincides with an Emergency, HOPEWELL shall<br \/>\n                  make all reasonable efforts to reschedule the Downtime.<\/p>\n<p>         9.       DAILY OPERATING REPORT FOR RECORD PURPOSES. HOPEWELL shall<br \/>\n                  keep NAPOCOR&#8217;s Power Management Center informed as to the<br \/>\n                  daily operating schedule and generation capability of its<br \/>\n                  Power Station, including, without limitation to, any Forced<br \/>\n                  Outages.<\/p>\n<p>         10.      OPERATING AND MAINTENANCE RECORDS. HOPEWELL shall maintain the<br \/>\n                  operating and maintenance records for each generating unit at<br \/>\n                  HOPEWELL&#8217;s Power Station for a period of at least five (5)<br \/>\n                  years with records of: real and reactive power production,<br \/>\n                  changes in operating status, outages, protective apparatus<br \/>\n                  operations and any unusual conditions found during<br \/>\n                  inspections. Changes in the setting of protective apparatus<br \/>\n                  shall also be logged. In addition, HOPEWELL shall maintain<br \/>\n                  records applicable to the Power Station, including the<br \/>\n                  electrical characteristics of the generator and settings or<br \/>\n                  adjustment of the generator control equipment and protective<br \/>\n                  devices. Such information shall be made available to NAPOCOR<br \/>\n                  upon request.<\/p>\n<p>                                       33<br \/>\n   37<\/p>\n<p>                                 THIRD SCHEDULE<\/p>\n<p>                PENALTY OF HOPEWELL ON DELAY OF COMPLETION DATE<\/p>\n<p>The following formula shall apply in computing the amount of penalty to be paid<br \/>\nby HOPEWELL to NAPOCOR due to delays:<\/p>\n<table>\n<s>   <c>   <c>       <c>    <c>              <c>    <c>            <c>    <c>             <c>    <c><br \/>\n                             Base Capacity           (  Nominal              Actual   )<br \/>\nP     =     (1\/Nd)    x      Payment per      x      ( Capacity     &#8211;       Capacity  )    x      1.05<br \/>\n                             kilowatt                (in kilowatt          in kilowatt)<br \/>\n<\/c><\/c><\/c><\/c><\/c><\/c><\/c><\/c><\/c><\/c><\/s><\/table>\n<p>where:<\/p>\n<p>         P        =        Amount to be paid by HOPEWELL to NAPOCOR for each day<br \/>\n                           of delay in respect of which HOPEWELL is required to<br \/>\n                           make a payment pursuant to Clause 5.03. Such amount<br \/>\n                           shall be payable on the last day of each calendar<br \/>\n                           month.<\/p>\n<p>         Nd       =        Number of days in the month.<\/p>\n<p>                                       34<br \/>\n   38<\/p>\n<p>                                FOURTH SCHEDULE<\/p>\n<p>            SPECIFICATIONS FOR FUEL SUPPLY AND START UP ELECTRICITY<\/p>\n<p>                                  FUEL SUPPLY<\/p>\n<p>                                 SPECIFICATIONS<\/p>\n<p>The specifications for the Fuel Supply will be as follows:<\/p>\n<table>\n<caption>\n         ITEM                                         FUEL ANALYSIS<br \/>\n                                             &#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-<br \/>\n                                             MIN.                       MAX.<br \/>\n<s>                                          <c>        <c>             <c><br \/>\nGravity, @ 36 (degrees) AP (Ave.)                       0.8448<br \/>\nViscosity, ssu at 100 (degrees) F             35                          50<br \/>\nFlash point, PM, (degrees) F                 130                          &#8212;<br \/>\nCloud point, (degrees) F                      &#8212;                          50<br \/>\nPour point, (degrees) F                       &#8212;                          50<br \/>\nWater &amp; Sediments, % Vol.                     &#8212;                        0.1<br \/>\nAsh %                                         &#8212;                        0.005<br \/>\nSulfur, Wt. %                                 &#8212;                        1.0<br \/>\nCalorific Value, BTU\/lb (LHV) (Ave.)                    18,400<br \/>\nTrace Metal Contaminants, ppm<br \/>\n   Sodium plus potassium                      &#8212;                        0.5<br \/>\n   Lead + Zinc                                &#8212;                        1<br \/>\n   Vanadium                                   &#8212;                        0.5<br \/>\n   Calcium                                    &#8212;                        2<br \/>\n   Nickel                                     &#8212;                        1<br \/>\n   Barium + Manganese + Phosphorous           &#8212;                        2<br \/>\nCarbon residue (10% bottom)                   &#8212;                        1<br \/>\n<\/c><\/c><\/c><\/s><\/caption>\n<\/table>\n<p>                                       35<\/p>\n<p>   39<\/p>\n<p>                              SUPPLY ARRANGEMENTS<\/p>\n<p>DELIVERY                    NAPOCOR and HOPEWELL will liaise to prepare weekly<br \/>\n                            fuel schedules showing anticipated times and<br \/>\n                            quantities of fuel to be utilized by the Power<br \/>\n                            Station and NAPOCOR shall be responsible for<br \/>\n                            ensuring the availability of fuel supplies, for the<br \/>\n                            payment therefor and for all arrangements with the<br \/>\n                            suppliers.<\/p>\n<p>FUEL OIL STORAGE            Fuel oil will be stored by NAPOCOR outside the Site<br \/>\nAND TANK FARM               in tanks of sufficient capacity to permit the fuel<br \/>\n                            to stand for at least 5 days after delivery to allow<br \/>\n                            water and solids to settle. The water shall be<br \/>\n                            drained off weekly.<\/p>\n<p>                            The tanks and tank farm will be constructed at<br \/>\n                            NAPACOR&#8217;s cost generally in accordance with figure 6<br \/>\n                            attached. The off Site fuel tanks are to be provided<br \/>\n                            with floating suctions and will be calibrated in an<br \/>\n                            approved manner. The tank farm shall be provided<br \/>\n                            with appropriate fire fighting facilities.<\/p>\n<p>TESTING                     Upon each delivery of fuel oil to an off Site tank<br \/>\n                            and, if so required by HOPEWELL, from time to time<br \/>\n                            thereafter, a suitable sample will be taken and<br \/>\n                            analysed jointly by HOPEWELL and NAPOCOR to ensure<br \/>\n                            that it meets the specifications as shown above. The<br \/>\n                            laboratory for analysing the oil will be agreed<br \/>\n                            between HOPEWELL and NAPOCOR.<\/p>\n<p>METERING                    Meters will be provided by NAPOCOR on the off Site<br \/>\n                            tanks. As a check, the off Site Tank ullages will be<br \/>\n                            taken before and after each delivery of fuel oil and<br \/>\n                            in the case of discrepancy, the ullages will<br \/>\n                            prevail. HOPEWELL will provide a fuel oil meter with<br \/>\n                            temperature compensation for measuring the delivery<br \/>\n                            of fuel oil from the off Site tanks. Such meter will<br \/>\n                            be installed within the Site area bounded by<br \/>\n                            permanent Site fence. Meters shall be tested every<br \/>\n                            six months at NAPOCOR&#8217;s cost by a third party agreed<br \/>\n                            between HOPEWELL and NAPOCOR.<\/p>\n<p>VARIATION IN RATE           HOPEWELL and NAPOCOR will liaise in estimating the<br \/>\nOF DELIVERY                 fuel required to comply with NAPOCOR&#8217;s annual,<br \/>\n                            monthly and weekly systems operating plans.<\/p>\n<p>                                       36<\/p>\n<p>   40<\/p>\n<p>Fuel Management            The parties will enter into a fuel management<br \/>\n                           agreement pursuant to which, for agreed fees,<br \/>\n                           HOPEWELL will undertake the day to day routine<br \/>\n                           maintenance and cleaning of the off Site tanks but<br \/>\n                           NAPOCOR shall be responsible for any repairs and\/or<br \/>\n                           replacement.<\/p>\n<p>Security                   NAPOCOR shall be responsible for all security and<br \/>\n                           safety arrangements in respect of the fuel in the off<br \/>\n                           Site tanks.<\/p>\n<p>Insurance                  NAPOCOR shall be responsible for effecting insurance,<br \/>\n                           acceptable to HOPEWELL in respect of the off Site<br \/>\n                           tanks and fuel stored therein and HOPEWELL shall be<br \/>\n                           named therein as a co-insured.<\/p>\n<p>                              START UP ELECTRICITY<\/p>\n<p>         3.5 MW at 13.8 KV if turbines started consecutively (normal<br \/>\n         operations).<\/p>\n<p>         7.5 MW at 13.8 KV is turbines started concurrently (in Emergency).<\/p>\n<p>                                       37<br \/>\n   41<br \/>\n                                 FIFTH SCHEDULE<\/p>\n<p>                        TRANSMISSION LINE SPECIFICATIONS<\/p>\n<p>Location<\/p>\n<p>         From the outgoing switching facility within the Site boundary at<br \/>\n         Navotas Fishing Port Complex as shown in figures 1 and 7 attached.<\/p>\n<p>Specifications<\/p>\n<p>         The transmission line shall be capable of providing sufficient<br \/>\n         electricity for testing, commissioning and starting the Power Station<br \/>\n         and shall be capable of taking the maximum output of the Power Station.<\/p>\n<p>                                       38<br \/>\n   42<\/p>\n<p>                                 SIXTH SCHEDULE<\/p>\n<p>                        ELECTRICITY DELIVERY PROCEDURES<\/p>\n<p>1.       Definition<\/p>\n<p>         &#8220;Downtime&#8221; means the minimum number of 12 hours per generating unit<br \/>\nper year allowed to HOPEWELL plus any further allowance for outage time per<br \/>\ngenerating unit calculated in accordance with Section 4 of this Schedule;<\/p>\n<p>         &#8220;Evaluated Operating Hour(s)&#8221; and &#8220;EOH&#8221; means the number of actual<br \/>\noperating hours per generating unit of the Power Station plus twenty (20)<br \/>\nhours times the number of starts per generating unit;<\/p>\n<p>         &#8220;Forced Outage&#8221; is defined as the inability due to the fault of<br \/>\nHOPEWELL to meet Contracted Capacity requested by NAPOCOR (other than as a<br \/>\nresult of any faults in or failure of the power transformers or high voltage<br \/>\nswitchgear) provided that any failure to meet the Contracted Capacity less any<br \/>\nreduction in the Availability of other units of the Power Station as a result<br \/>\nof scheduled Downtime shall not be Forced Outage;<\/p>\n<p>         &#8220;Forced Outage Day&#8221; means a day on which, due to Forced Outage,<br \/>\nHOPEWELL failed for a continuous period in excess of 30 minutes to deliver<br \/>\npower at least 95% of the amount of KW requested by NAPOCOR.<\/p>\n<p>2.       Measurement of Power Generated<\/p>\n<p>         Measurement of power generated transferred to NAPOCOR shall be made at<br \/>\n         the high voltage side of the main power transformer.<\/p>\n<p>3.       Notice in change of output<\/p>\n<p>         Specific procedures for notifications of power requirements shall be<br \/>\n         agreed between HOPEWELL and NAPOCOR prior to the Completion Date.<br \/>\n         Subject to such procedures, the outputs of the gas turbine generators<br \/>\n         shall be as required by the system controller from time to time,<br \/>\n         provided that changes in output requested by the system controller<br \/>\n         remain within the Specifications and the Operating Parameters.<\/p>\n<p>4.       Notice of Downtime<\/p>\n<p>         NAPOCOR shall prepare annual, monthly and weekly systems operating<br \/>\n         plans and in so doing shall coordinate with HOPEWELL to agree on the<br \/>\n         Downtime.<\/p>\n<p>                                       39<br \/>\n   43<\/p>\n<p>         NAPOCOR shall grant HOPEWELL sufficient Downtime to undertake all<br \/>\n         regular inspection and maintenance of the gas turbine generators in<br \/>\n         accordance with the manufacturer&#8217;s recommendations, taking full account<br \/>\n         of hours run, number of starts and duration of running for each start.<\/p>\n<p>         HOPEWELL will be allowed the following Downtime on the basis of<br \/>\n         Evaluated Operating Hours:-<\/p>\n<table>\n<caption>\n              Evaluated Operating Hours           Outage Time<br \/>\n              &#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-           &#8212;&#8212;&#8212;&#8211;<br \/>\n              <s>                                 <c><br \/>\n                    4000 EOH\/unit                  72 hours<br \/>\n                    8000 EOH\/unit                   7 days<br \/>\n                   12000 EOH\/unit                  72 hours<br \/>\n                   16000 EOH\/unit                   5 weeks<br \/>\n                   20000 EOH\/unit                  72 hours<br \/>\n                   24000 EOH\/unit                   7 days<br \/>\n                   28000 EOH\/unit                  72 hours<br \/>\n                   32000 EOH\/unit                   5 weeks<br \/>\n                   36000 EOH\/unit                  72 hours<br \/>\n                   40000 EOH\/unit                   7 days<br \/>\n                   44000 EOH\/unit                  72 hours<br \/>\n                   48000 EOH\/unit                   8 weeks<br \/>\n<\/c><\/s><\/caption>\n<\/table>\n<p>         Following a Major Overhaul of a gas turbine of Evaluated Operating<br \/>\n         Hours will, for the purposes of calculating Downtime, return to zero.<\/p>\n<p>         HOPEWELL will plan with NAPOCOR to ensure that as far as practicable,<br \/>\n         Downtime is undertaken at times to cause minimum disruption to the<br \/>\n         NAPOCOR power system.<\/p>\n<p>5.       NOTICE OF REQUIRED ELECTRICITY<\/p>\n<p>         Whilst the annual, monthly and weekly system operating plans will be<br \/>\n         prepared by NAPOCOR in consultation with HOPEWELL, it is agreed that<br \/>\n         the weekly plan for the following seven days will be the control plan<br \/>\n         and will be that plan referred to as &#8220;normal operation plan&#8221;.<\/p>\n<p>6.       NORMAL OPERATIONS<\/p>\n<p>         Normal operations of the gas turbines are as defined below:-<\/p>\n<p>         (1)      Operating in accordance with the weekly normal operation plan<br \/>\n                  as defined in Section 5 above as agreed in writing between<br \/>\n                  NAPOCOR and HOPEWELL with no more than one start per day.<\/p>\n<p>         (2)      Operating with fuel within the specification set out in the<br \/>\n                  Fourth Schedule.<\/p>\n<p>                                       40<\/p>\n<p>   44<br \/>\n         (3)      Subject to the provisions of Clause 5.05, operating at 200 MW<br \/>\n                  with an ambient temperature not exceeding 37(degrees)C.<\/p>\n<p>         (4)      Operating with an adequate supply of water as specified in<br \/>\n                  Section VI of the First Schedule.<\/p>\n<p>         (5)      Start up power of 3.5 MW at 13.8 KV is available (normal<br \/>\n                  operations is to start units consecutively).<\/p>\n<p>         (6)      Operating frequencies of the system to be within the limits of<br \/>\n                  the Operating Parameters.<\/p>\n<p>         (7)      Operating at a system voltage of 110 KV plus or minus 5%.<\/p>\n<p>         (8)      Start-up, synchronising and loading to be within the limits of<br \/>\n                  the Operating Parameters.<\/p>\n<p>         (9)      Full access to the Site at all times for materials and<br \/>\n                  personnel.<\/p>\n<p>                                       41<\/p>\n<p>   45<br \/>\n                                SEVENTH SCHEDULE<\/p>\n<p>                    MEASUREMENT AND RECORDING OF ELECTRICITY<\/p>\n<p>1.       The meter locations to record the KW and KWH delivered to NAPOCOR shall<br \/>\n         be as shown in figure 7 attached.<\/p>\n<p>2.       The quantity of power and energy delivered to NAPOCOR shall be given by<br \/>\n         the in\/out meters M1 + M2.<\/p>\n<p>3.       In order to verify the quantity of electricity delivered by HOPEWELL to<br \/>\n         NAPOCOR in each Month, NAPOCOR and HOPEWELL shall at noon or at such<br \/>\n         other time agreed between NAPOCOR and HOPEWELL on the twenty fifth day<br \/>\n         of each month take a photograph of the electricity meters in the Power<br \/>\n         Station recording the supply of electricity by HOPEWELL Provided always<br \/>\n         that if either party shall not be present at the relevant meter or<br \/>\n         meters at the agreed time, the above mentioned photograph shall be<br \/>\n         taken by the party present and shall be binding on the party absent.<\/p>\n<p>4.       HOPEWELL shall supply and install and NAPOCOR shall maintain as part of<br \/>\n         the interconnection facilities, meters and related equipment to be<br \/>\n         utilized for the measurement of electric power and energy in<br \/>\n         determining NAPOCOR&#8217;s payments to HOPEWELL pursuant to this Agreement.<\/p>\n<p>5.       For the purpose of monitoring the Power Station&#8217;s operation, NAPOCOR<br \/>\n         shall have the right to require, at HOPEWELL&#8217;s expense, the<br \/>\n         installation of metering devices at the generation side which will be<br \/>\n         specified to HOPEWELL prior to the Effective Date.<\/p>\n<p>6.       The meters, installed in pursuance to this Agreement, shall be tested<br \/>\n         by NAPOCOR at its own expense every six months. Other tests may be<br \/>\n         conducted at any reasonable time upon request by either party, at the<br \/>\n         requesting party&#8217;s expense. If HOPEWELL makes such request, HOPEWELL<br \/>\n         shall reimburse said expense to NAPOCOR within thirty (30) days after<br \/>\n         presentation of a bill therefor. NAPOCOR&#8217;s meter test result shall be<br \/>\n         deemed final and conclusive.<\/p>\n<p>7.       The meters and metering transformers shall be in accordance with<br \/>\n         NAPOCOR&#8217;s specifications.<\/p>\n<p>8.       Metering equipment found to be inaccurate shall be repaired, adjusted,<br \/>\n         or replaced by NAPOCOR at HOPEWELL&#8217;s expense such that the accuracy of<br \/>\n         said equipment shall be 100%. If metering equipment inaccuracy exceeds<br \/>\n         plus or minus two percent (2%), the correct amount of energy delivered<br \/>\n         during the period of said inaccuracy shall be estimated by NAPOCOR and<br \/>\n         agreed by the parties. Adjustment for meter inaccuracy shall cover only<br \/>\n         the current Month and the Month immediately preceding it.<\/p>\n<p>                                       42<\/p>\n<p>   46<\/p>\n<p>                                EIGHTH SCHEDULE<\/p>\n<p>                          DELIVERY OF POWER AND ENERGY<\/p>\n<p>1.       OBLIGATIONS OF PARTIES.  HOPEWELL hereby agrees to convert fuel<br \/>\n         supplied by NAPOCOR into electricity and NAPOCOR hereby agrees to take<br \/>\n         at the high voltage side of the step-up transformer, the electric<br \/>\n         power and energy delivered by HOPEWELL to NAPOCOR until the end of the<br \/>\n         Co-operation Period.<\/p>\n<p>2.       CAPACITY PROVISION.  HOPEWELL shall provide and NAPOCOR shall pay for<br \/>\n         the electric power output capacity of the Power Station as provided in<br \/>\n         Section 5.1 of this Schedule in respect of the amount of Contracted<br \/>\n         Capacity which, in respect of each year, shall be the actual net<br \/>\n         Kilowatt (KW) capability of the Power Station nominated by HOPEWELL<br \/>\n         for such year provided that:-<\/p>\n<p>         a.       such nominated amount may not exceed 105% of the Nominal<br \/>\n                  Capacity unless NAPOCOR so agrees; and<\/p>\n<p>         b.       if, at the beginning of any year HOPEWELL nominates an amount<br \/>\n                  less than 95% of the Nominal Capacity it may subsequently<br \/>\n                  nominate an increased amount in which case such increased<br \/>\n                  amount shall be the Contracted Capacity for the remainder of<br \/>\n                  such year.<\/p>\n<p>         At the commencement of each year of the Co-operation Period, if so<br \/>\n         requested by NAPOCOR, HOPEWELL shall demonstrate its ability to<br \/>\n         provide NAPOCOR the Contracted Capacity within 14 days of any<br \/>\n         nomination by HOPEWELL.<\/p>\n<p>         If, on the Completion Day or any anniversary thereof HOPEWELL fails to<br \/>\n         notify NAPOCOR of the nominated amount of Contracted Capacity for the<br \/>\n         following year, the Contracted Capacity for such year shall be 200,000<br \/>\n         KW.<\/p>\n<p>3.       DELIVERED ENERGY.  HOPEWELL shall convert fuel supplied by NAPOCOR<br \/>\n         into electricity and deliver it to NAPOCOR, and NAPOCOR shall take<br \/>\n         such electricity from HOPEWELL as requested by the NAPOCOR Power<br \/>\n         Management Center. The energy delivered shall be paid for by NAPOCOR<br \/>\n         pursuant to the terms and conditions as provided in Section 5.2 of<br \/>\n         this Schedule.<\/p>\n<p>4.       START UPS.  NAPOCOR shall pay HOPEWELL for each start up of the gas<br \/>\n         turbines as provided in Section 5.3 of this Schedule.<\/p>\n<p>                                       43<br \/>\n   47<\/p>\n<p>5.       TERMS OF PAYMENT<\/p>\n<p>         5.1      CAPACITY FEES.  Capacity Fees shall be computed on the basis<br \/>\n                  of the following formula:<\/p>\n<p>         A  =  {[(BCR * CC)(1 &#8211; TFOD\/Nd)] &#8211; [(y * 1.05)(BCR)(NC &#8211; CC)]}<\/p>\n<p>                  where:<\/p>\n<p>                  A        =        Total Capacity Payment in Dollars for the<br \/>\n                                    Month<\/p>\n<p>                  BCR      =        Base Capacity Rate in $\/KW\/Month<\/p>\n<p>                  NC       =        Nominal Capacity, in KW<\/p>\n<p>                  TFOD     =        Total Forced Outage Days<\/p>\n<p>                  Nd       =        Total No. of Days in the Month<\/p>\n<p>                  CC       =        Contracted Capacity for the year, in KW<\/p>\n<p>                  y        =        variable<\/p>\n<p>                  The Base Capacity Rate shall be $3.225 KW\/Month.<\/p>\n<p>                  The variable y is defined as follows:<\/p>\n<p>                           if 0.95 NC <\/p>\n<caption>\n                                                             Maximum Fluctuation<br \/>\n                                                             &#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-<br \/>\n                           <s>                               <c><br \/>\n                           Compressor inlet air temperature       + 1.5 degree C<br \/>\n                                                                  _<\/p>\n<p>                           Fuel rate                              + 2%<br \/>\n                                                                  _   <\/p>\n<p>                           Speed of load turbine                  + 1%<br \/>\n                                                                  _<\/p>\n<p>                           Measured load                          + 2%<br \/>\n                                                                  _   <\/p>\n<p>                  (f)      The tests will be conducted using normal operating<br \/>\n                           fuel with specifications in accordance with the<br \/>\n                           Fourth Schedule. Fuel heating value and specific<br \/>\n                           gravity will be determined by a properly qualified<br \/>\n                           laboratory.<\/p>\n<p>                  (g)      Test readings for the Guarantee Tests will be<br \/>\n                           recorded at ten minutes intervals during a one hour<br \/>\n                           period after the units have achieved a steady state<br \/>\n                           condition.<\/p>\n<p>                  (h)      Instrumentation<\/p>\n<p>                           Instruments used to measure performance are all panel<br \/>\n                           instruments unless otherwise mentioned.<\/p>\n<p>                                       59<br \/>\n   63<\/p>\n<p>                           Only those measurement items marked with an asterisk<br \/>\n                           (see Table I) are required for the Guarantee Tests.<\/p>\n<p>                  Instruments used to measure the quantities required for the<br \/>\n                  Guarantee Tests will be calibrated over their expected<br \/>\n                  operating ranges.<\/p>\n<p>                  In addition other instruments will be monitored to ensure the<br \/>\n                  units are operated under steady state conditions.<\/p>\n<p>         (4)      TOLERANCE<\/p>\n<p>                  Only output and heat rate at MCR are guaranteed with<br \/>\n                  tolerance.<\/p>\n<p>                  The measuring tolerance values at MCR are as follows:<\/p>\n<p>                  Tolerance of output        :        1.75%<\/p>\n<p>                  Tolerance of heat rate     :        3.0%<\/p>\n<p>         (5)      HEAT RATE CALCULATION<\/p>\n<p>                  Station Heat Rate,  Btu         Total Heat of Fuel Input<br \/>\n                                      &#8212;  =      &#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;<br \/>\n                                      KWh         Net Electrical Power Output<\/p>\n<p>                  Total Heat Input of Fuel, Btu = Weight of Fuel Input,<br \/>\n                                            &#8212;<br \/>\n                                            hr<\/p>\n<p>                                                  lb x Heating Value, Btu<br \/>\n                                                  &#8212;                  &#8212;<br \/>\n                                                  hr                  lb<\/p>\n<p>                  Net Electrical output is measured by the KWhr meter on the<br \/>\n                  high voltage side of the generator transformer.<\/p>\n<p>                  Note:    The Tested Plant Net Guaranteed Net Heat Rate is the<br \/>\n                           weighted average of the Tested Plant Net Heat Rates<br \/>\n                           of the Guarantee Tests.<\/p>\n<p>II.      Information Tests<\/p>\n<p>         (1)      PURPOSE OF INFORMATION TESTS<\/p>\n<p>                  To provide information only on the operating characteristics<br \/>\n                  of the Power Station and its performance at various<br \/>\n                  conditions.<\/p>\n<p>         (2)      GENERATOR TESTS<\/p>\n<p>                  The following tests will be conducted at the time of the<br \/>\n                  Guarantee Tests or as agreed between HOPEWELL and NAPOCOR.<\/p>\n<p>                                       60<\/p>\n<p>   64<\/p>\n<table>\n<caption>\n&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-<\/p>\n<p>No.           Test Items               Symbol               Remarks<br \/>\n&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-<br \/>\n<s>     <c>                            <c>         <c><br \/>\n1       Insulation resistance test         0       By a 1.000V megger for<br \/>\n                                                   alternator armature windings.<br \/>\n                                                   By 500 V megger for field.<\/p>\n<p>2       Temperature rise test              0       Temperature rise test will<br \/>\n                                                   be made with the machine<br \/>\n                                                   operating at rated loading<br \/>\n                                                   condition.<\/p>\n<p>3       Vibration test                     0       Vibration will be measured<br \/>\n                                                   at no-load and load.<\/p>\n<p>4       Insulation of bearing              0       Bearing insulation will be<br \/>\n                                                   checked at installation.<br \/>\n<\/c><\/c><\/c><\/s><\/caption>\n<\/table>\n<p>         (3)      INSTRUMENTATION<\/p>\n<p>                  The measurement items which are not asterisked in Table I are<br \/>\n                  to be tested as part of the Information Tests.<\/p>\n<p>                  In addition to the measurement items listed in Table I, the<br \/>\n                  following information will also be taken:<\/p>\n<p>                    (i)    Lube oil header pressure and temperature<\/p>\n<p>                   (ii)    Bearing drain temperature<\/p>\n<p>                  (iii)    Wheel space temperature<\/p>\n<p>                                       61<\/p>\n<p>   65<br \/>\n                                    TABLE I<\/p>\n<p>                     Instrumentation for Heat Rate Testing<\/p>\n<table>\n<caption>\n&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-<br \/>\nMeasurement                            Primary                Secondary           Location of<br \/>\nItem                       Qty.        Device                 Device              Primary Dev.<br \/>\n&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-<br \/>\n<s>                        <c>         <c>                    <c>                <c><br \/>\n* Atmospheric                1         Barometer                &#8212;               In plant at<br \/>\n  pressure                                                                       turbine level<\/p>\n<p>* Compressor                 2         Thermometer              &#8212;               Inlet to air<br \/>\n  inlet temp.                                                                    filter<\/p>\n<p>  Compressor                 2         Thermocouple           Unit               Compressor dis-<br \/>\n  discharge                                                   temp.              charge passage<br \/>\n  temp.                                                       ind.<\/p>\n<p>  Compressor                 1         Pressure               Unit               Compressor dis-<br \/>\n  discharge                            gauge                  pressure           charge passage<br \/>\n  pressure                                                    gauge<\/p>\n<p>  Turbine speed                        Generator                &#8212;                At generator<br \/>\n                                       frequency                                  panel<br \/>\n                                       meter<\/p>\n<p>  Turbine                   12         Thermocouple           Unit                Exhaust duct<br \/>\n  exhaust temp.                                               temp.<br \/>\n                                                              ind.<\/p>\n<p> *Fuel flow                  1         Fuel flow                &#8212;                Fuel supply<br \/>\n                                       meter                                      line<\/p>\n<p> *Fuel temp.                 1         Thermometer              &#8212;                At fuel meter<\/p>\n<p> *Fuel specific              1             &#8212;                 Lab.                      &#8212;<br \/>\n  gravity                                                     tests<\/p>\n<p> *Fuel heating               1             &#8212;                  Lab.                     &#8212;<br \/>\n  value                                                       tests<\/p>\n<p>  Generator                  1         Unit                   Kilowatt            At generator<br \/>\n  output                               instrument             hour                panel<br \/>\n                                       transformer            meter<\/p>\n<p> *Net power                  1         Precision                &#8212;                HV side of<br \/>\n  output                               kilowatt                                   transformer<br \/>\n                                       hour meter<br \/>\n<\/c><\/c><\/c><\/c><\/s><\/caption>\n<\/table>\n<p>                                       62<\/p>\n<p>   66<br \/>\n                               FIFTEENTH SCHEDULE<\/p>\n<p>                    SAMPLE COMPUTATIONS OF MONTHLY BILLINGS,<br \/>\n                    START-UP CHARGES, PENALTIES AND BONUSES<\/p>\n<p>I.      BONUS FOR EARLY COMPLETION<\/p>\n<p>         Data and Assumptions:<\/p>\n<p>         &#8211;        100 MW completion on June 1, 1989 and able to operate through<br \/>\n                  June 25, 1989 without Forced Outage.<\/p>\n<p>         &#8211;        Metered energy delivered on June 25, 1989 = 5,500,00 KWH<\/p>\n<p>         &#8211;        Tested Plant Net Heat Rate = 12,300 BTU\/KWH<\/p>\n<p>         1.       Capacity Fee = (BCR*CC) (1-TFOD\/Nd) &#8211; (Y*1.05)(BCR) (NC-CC)<\/p>\n<p>                  where:   BCR     =    $3.225\/KW\/month<br \/>\n                           NC = CC =    100,000 KW<br \/>\n                           TFOD    =    6 days (May 26 to May 31 i.e. including<br \/>\n                                                days before completion)<br \/>\n                           Nd      =    Total number of days = 31 days (May 26<br \/>\n                                        to June 25)<br \/>\n                           Y       =    variable = 0<\/p>\n<p>                  Capacity fee     =    ($3.225*100,000) * (1-6\/31 &#8211; 0<br \/>\n                                   =    $322,500 * 25\/31<br \/>\n                                        $260,080.64     <\/p>\n<p>         2.       Energy Fee       =    (BER*ED) + 0 (Vg-Vt)     <\/p>\n<p>                  where:   BER     =    $0.003\/KWH plus Ps0.023\/KWH<br \/>\n                           ED      =    5,500,000 KWH               <\/p>\n<p>                  Energy Fee       =    5,500,00 * ($0.003 + Ps0.023)<br \/>\n                                        $16,500.00 plus Ps126,500.00          <\/p>\n<p>         3.       Total Bonus      =    $260,080.64 + $16,500.00 + Ps126,500.00<br \/>\n                                   =    $276,580.64 plus Ps126,500.00 <\/p>\n<p>II.      PENALTY FOR DELAYED COMPLETION<\/p>\n<p>         Data and assumptions:<\/p>\n<p>         &#8211;        lst 100 MW completion on June 1, 1989 with 5,500,000 KWH<br \/>\n                  monthly energy<\/p>\n<p>         &#8211;        2nd 100 MW completion on November 1, 1989 with 5,500,000 KWH<br \/>\n                  monthly energy<\/p>\n<p>         &#8211;        Tested Plant Net Heat Rate = guaranteed 12,300 BTU\/KWH<\/p>\n<p>                                       63<br \/>\n   67<\/p>\n<table>\n<s>      <c>                                                      <c><br \/>\n1.       Billing period August 26 through<br \/>\n         September 25, 1989, still Bonus:<\/p>\n<p>         CF   =    $3.225 x 100,000                               =     $322,500.00<br \/>\n         EF   =    5,500,000 x ($0.003 + Ps0.023)                 =     $ 16,500.00<br \/>\n                                                                  +    Ps126,500.00<br \/>\n                                                                       &#8212;&#8212;&#8212;&#8212;<br \/>\n                                      Total Bonus                 =     $339,000.00<br \/>\n                                                                  +    Ps126,500.00<\/p>\n<p>2.       Billing period September 26 through<br \/>\n         October 25, 1989:<\/p>\n<p>         CF   =    $3.225 x 100,000                               =     $322,500.00<br \/>\n         EF   =    5,500,000 x ($0.003 + Ps0.023)                 =     $ 16,500.00<br \/>\n                                                                  +    Ps126,500.00<br \/>\n                                                                       &#8212;&#8212;&#8212;&#8212;<br \/>\n                                      Gross Fee                   =     $339,000.00<br \/>\n                                                                  +    Ps126,500.00<\/p>\n<p>         Penalty for period October 16 through<br \/>\n         October 25, 1989:<\/p>\n<p>         Capacity penalty = $3.225 x 100,000 x 10\/30 x 1.05       =     $112,875.00<\/p>\n<p>                                      Total Net Billing           =     $226,125.00<br \/>\n                                                                  +    Ps126,500.00<\/p>\n<p>3.      Billing period October 26 through<br \/>\n        November 25, 1989:<\/p>\n<p>         &#8211;        For lst 100 MW power &amp; energy delivery          =     $339,000.00      <\/p>\n<p>         &#8211;        For 2nd 100 MW power &amp; energy delivery<\/p>\n<p>                  CF = $3.225 * 100,000 x 25\/31                   =     $260,080.65<br \/>\n                  EF = 5,500,000 * (25\/31) * (0.003 + Ps0.023)          $ 13,306.45<br \/>\n                                                                  +    Ps102,016.12<\/p>\n<p>         &#8211;        Penalty for period October 16 through<br \/>\n                  October 31, 1989:                               =     $ 67,725.00<br \/>\n                                                                       &#8212;&#8212;&#8212;&#8212;<br \/>\n         &#8211;        Penalty = (6\/30) * $3.225 * 100,000 x 1.05<\/p>\n<p>                                      Total Net Billing           =     $544,662.10<br \/>\n                                                                  +    Ps102,016.12<br \/>\n<\/c><\/c><\/s><\/table>\n<p>                                       64<br \/>\n   68<\/p>\n<p>III.     PENALTY AND LIQUIDATED DAMAGES<\/p>\n<p>         If no capacity of the Power Station is completed 300 days after Target<br \/>\n         Completion Date of October 15, 1989:<\/p>\n<table>\n         <s>                          <c>                               <c><br \/>\n         1) Capacity Penalty = $3.225 * 200,000 * 12 * 300\/365          = $ 6,679,725.80<br \/>\n         2) Liquidated Damages        * 1.05                            = $ 4,200,000.00<br \/>\n                                                                          &#8212;&#8212;&#8212;&#8212;&#8211;<br \/>\n                                                      Total             = $10,879,725.80<br \/>\n                                                                          ==============<br \/>\n<\/c><\/c><\/s><\/table>\n<p>IV.      NORMAL CONDITION MONTHLY BILLING<\/p>\n<p>         Data and Assumptions:<\/p>\n<p>         Nominal Capacity = Contracted Capacity = 200,000 KW<\/p>\n<p>         Monthly Energy Delivery = 14,600,000 KWH<\/p>\n<p>         1.       If no Forced Outage or scheduled Downtime<\/p>\n<table>\n                  <s>                                                   <c><br \/>\n                  CF   = BCR * CC                                       = $   645,000.00<br \/>\n                       = $3.225 * 200,000<\/p>\n<p>                  EF   = ED * BER                                       = $    43,800.00<br \/>\n                       = 14,000,600 x $0.003 + Ps0.023                  + Ps  335,800.00<br \/>\n                                                                          &#8212;&#8212;&#8212;&#8212;&#8211;<\/p>\n<p>                                                      Sub-Total         = $   668,800.00<br \/>\n                                                                        + Ps  335,800.00<br \/>\n                                                                          ==============<\/p>\n<p>                  Start-up Fee:<\/p>\n<p>                  Assume: 21 start-ups\/month at 30 minutes<\/p>\n<p>                         Energy = 3,500 KW x 0.5 x 21 = 36,750 KWH<\/p>\n<p>                  Start-up fee = 36,750 * ($0.003 + Ps0.023)            =  $      110.25<br \/>\n                                                                        + Ps      845.25<\/p>\n<p>                                                      Total Bill        =  $  688,910.25<br \/>\n                                                                        + Ps  336,645.25<br \/>\n                                                                          &#8212;&#8212;&#8212;&#8212;&#8211;<\/p>\n<p>         2.       If during the Month, any of the units were on Forced Outage<br \/>\n                  for a total of five (5) days or that the Power Station failed<br \/>\n                  to provide 200 MW as called upon by NPC load dispatcher for a<br \/>\n                  total of five (5) times:<\/p>\n<p>                  CF = $3.225 * 200,000 * (1-5\/30)                      =  $  537,500.00<br \/>\n                  EF = 14,600,000 * ($0.003 + Ps0.023)                  =  $   43,800.00<br \/>\n                                                                        + Ps  335,800.00<br \/>\n                                                                          &#8212;&#8212;&#8212;&#8212;&#8211;<br \/>\n                                                      Total Bill        =  $  581,300.00<br \/>\n                                                                        + Ps  335,800.00<br \/>\n                                                                          ==============<br \/>\n<\/c><\/s><\/table>\n<p>                  NOTE: Penalty = $107,500.00<\/p>\n<p>                                       65<br \/>\n   69<\/p>\n<p>         3.       If during the Month, one of the units (50,000 kW capacity)<br \/>\n                  accumulated an EOH of 4000 hours but exceeded its allowable<br \/>\n                  Downtime per the maintenance schedule:<\/p>\n<p>                  Total no. of Downtime days           =   5    days<\/p>\n<p>                  Allowable Downtime:<\/p>\n<p>                           Per Item 1, Schedule Six    =    1\/2 day<br \/>\n                           Per Item 4, Schedule Six    =   3    days<\/p>\n<p>                              Total Allowable Downtime =   3-1\/2 days<\/p>\n<p>                  Forced Outage  5 &#8211; 3\/12 = 1-1\/2 days<\/p>\n<p>                       CF = ($3.225 x 200,000) (1 &#8211; 1.5\/30)<br \/>\n                          =  $645,000 x (1 &#8211; 0.05)<br \/>\n                          =  $645,000 x 0.95<br \/>\n                          =  $612,750               <\/p>\n<p>                 Penalty  =  $32,250<\/p>\n<p>V.       Penalty\/Bonus due to deviation from Guaranteed Plant Net Heat Rate<\/p>\n<p>         Penalty Bonus    =  0 (Vg-Vt)<\/p>\n<p>                    Vt    =  ED * HR(g) * lLHV * 1\/d   <\/p>\n<p>         where:      O    =  Price of fuel = $0.1524 or P3.20\/litre<br \/>\n                  HR(g)   =  12,300 BTU\/KWH Guaranteed Plant Net Heat Rate<br \/>\n                     d    =  1.85 lb\/litre density of fuel<br \/>\n                    ED    =  14,600,000 KWH delivered energy per month<\/p>\n<p>         1.      If HR(t) = 12,546 BTU\/KWH as tested at Commissioning Date<\/p>\n<p>                 then:<\/p>\n<p>                           Vg      =   14,600,000 x 12,300 x 1\/18,400 x 1\/1.85<br \/>\n                                   =    5,275,558.167 litres\/month<\/p>\n<p>                           Vt      =   14,600,000 * 12,546 * 1\/18,400 * 1\/1.85<br \/>\n                                   =    5,381,069.33 litres\/month<\/p>\n<p>                  Thus, for the lst 6,000 EOH (more or less one year operation)<\/p>\n<p>                  (Penalty\/month   =    0 (Vg-Vt)<br \/>\n                                   =    $0.1524 (5,275,558.167 &#8211; 5,381,069.33)<br \/>\n                                   =    $16,079.89\/month<\/p>\n<p>                                       66<br \/>\n   70<\/p>\n<p>         2.       If HR(t) = 12,054 BTU\/KWH as tested at Commissioning Date<\/p>\n<p>                  then:<\/p>\n<p>                     Vt  =   14,600,000 x 12,054 x 1\/18,400 x 1\/1.85<br \/>\n                         =    5,170,047.004 litres\/month<\/p>\n<p>                  Thus, for the lst 6,000 EOH (more or less one year operation)<\/p>\n<p>                  Bonus\/month  =  $0.1524 (5,275,558.167 &#8211; 5,170,047.004)<\/p>\n<p>                               =  $16,079.89\/month<\/p>\n<p>         3.       If HR(t) = 12,669 BTU\/KWH as tested after 6,000 EOH<br \/>\n                             (more or less 2nd year)<\/p>\n<p>                  then:<\/p>\n<p>                     HR(g) = 12,300 * 1.006 = 12,373 BTU\/KWH<br \/>\n                     V(g)  = 14,600,000 * 12,373 * 1\/18,400 * 1\/1.85<br \/>\n                           =  5,306,868.2 litres\/month<\/p>\n<p>                  Thus, for the 2nd 6,000 EOH (2nd year operation)<\/p>\n<p>                  Penalty\/month = $0.1524 (5,306,868.2 &#8211; 5,433,824.8)<br \/>\n                                = $19,348.18\/month<\/p>\n<p>         4.       If HR(t) = 12,263 BTU\/KWH as tested after 6,000 EOH (more or<br \/>\n                  less 2nd year)<\/p>\n<p>                  then:<\/p>\n<p>                           V(t) =  14,600,000 * 12,263 * 1\/18,400 * 1\/1.85<br \/>\n                                =   5,259,688.5 litres\/month<\/p>\n<p>                  Bonus\/month   = $0.1524 (5,306,868.2 &#8211; 5,259,688.5)<br \/>\n                                = $ 7,190.18\/month<\/p>\n<p>                                       67<\/p>\n<p>   71<br \/>\nNATIONAL POWER CORPORATION<\/p>\n<p>By:<\/p>\n<p>   &#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-<br \/>\n            ERNESTO M. ABOITIZ<\/p>\n<p>Telex:          40120 NAPOCOR PM<br \/>\nFax:            2 9224 339<\/p>\n<p>HOPEWELL PROJECT MANAGEMENT COMPANY LIMITED<\/p>\n<p>By:<\/p>\n<p>   &#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-<br \/>\n                  GORDON WU<\/p>\n<p>Telex:          72485 HOWEL HX<br \/>\nFax:            5-8612068<\/p>\n<p>                                       68<br \/>\n   72<\/p>\n<p>                                    [CHART]<\/p>\n<p>NOTE:<\/p>\n<p>         1.  COORDINATES (X,Y) SHOWN IN THIS DRAWING ARE NOT FINAL AND ARE<br \/>\n             ASSUMED. FINAL COORDINATES SHALL BE VERIFIED AND ESTABLISHED IN<br \/>\n             THE FIELD BY THE EFFECTIVE DATE.<\/p>\n<p>                                 LOCATION PLAN<\/p>\n<p>                                    FIGURE 1<br \/>\n   73<br \/>\n                                    [CHART]<\/p>\n<p>                        DETAIL: TEMPORARY FENCE and GATE<br \/>\n                        &#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8211;<br \/>\n                                    FIGURE 2<br \/>\n   74<\/p>\n<p>                                    [CHART]<\/p>\n<p>                    PROPOSED 200 MW GAS TURBINE POWER PLANT<br \/>\n                              SINGLE LINE DIAGRAM<\/p>\n<p>                           NATIONAL POWER CORPORATION<br \/>\n                              DILIMAN, QUEZON CITY<\/p>\n<p>   75<\/p>\n<p>                                    [CHART]<\/p>\n<p>                                SCOPE OF SUPPLY<br \/>\n                                    FIGURE 4<\/p>\n<p>   76<\/p>\n<p>                                    [CHART]<\/p>\n<p>                                SCOPE OF SUPPLY<br \/>\n                                   FIGURE 4A<br \/>\n   77<br \/>\n              PROPOSED SCHEME OF DILIMAN &#8212; NAVOTAS \/ MALABON LINK<\/p>\n<p>                                    [CHART]<\/p>\n<p>                                 COMMUNICATION<\/p>\n<p>                                    FIGURE 5<br \/>\n   78<br \/>\n                                    [CHART]<\/p>\n<p>                            FUEL OIL HANDLING SYSTEM<br \/>\n                               SCHEMATIC DIAGRAM<\/p>\n<p>                                    FIGURE 6<br \/>\n   79<br \/>\n                                    [CHART]<\/p>\n<p>                                    METERING<br \/>\n                                    FIGURE 7<br \/>\n<\/c><\/s><\/caption>\n","protected":false},"template":"","meta":{"_acf_changed":false,"_stopmodifiedupdate":true,"_modified_date":"","_cloudinary_featured_overwrite":false},"corporate_contracts_companies":[8237],"corporate_contracts_industries":[9534],"corporate_contracts_types":[9613,9620],"class_list":["post-42107","corporate_contracts","type-corporate_contracts","status-publish","hentry","corporate_contracts_companies-mirant-corp","corporate_contracts_industries-utilities__electric","corporate_contracts_types-operations","corporate_contracts_types-operations__services"],"acf":[],"_links":{"self":[{"href":"https:\/\/corporate.findlaw.com\/legal-api\/wp-json\/wp\/v2\/corporate_contracts\/42107","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/corporate.findlaw.com\/legal-api\/wp-json\/wp\/v2\/corporate_contracts"}],"about":[{"href":"https:\/\/corporate.findlaw.com\/legal-api\/wp-json\/wp\/v2\/types\/corporate_contracts"}],"wp:attachment":[{"href":"https:\/\/corporate.findlaw.com\/legal-api\/wp-json\/wp\/v2\/media?parent=42107"}],"wp:term":[{"taxonomy":"corporate_contracts_companies","embeddable":true,"href":"https:\/\/corporate.findlaw.com\/legal-api\/wp-json\/wp\/v2\/corporate_contracts_companies?post=42107"},{"taxonomy":"corporate_contracts_industries","embeddable":true,"href":"https:\/\/corporate.findlaw.com\/legal-api\/wp-json\/wp\/v2\/corporate_contracts_industries?post=42107"},{"taxonomy":"corporate_contracts_types","embeddable":true,"href":"https:\/\/corporate.findlaw.com\/legal-api\/wp-json\/wp\/v2\/corporate_contracts_types?post=42107"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}